{"title":"Gas Pool \u0026 Spa Heaters","description":"\u003cp\u003e\u003cstrong\u003eGas Pool \u0026amp; Spa Heaters\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/hx-70-gas-heater-by-astralpool-hurlcon-hx70\" title=\"AstralPool HX 70 \/ Hurlcon HX70 Gas Spa Heater\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan style=\"color: #000000;\"\u003eHeat-up Times Chart (Raise Water by 10°C)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eUse this as a quick guide to estimate how long each heater size may take to lift your pool or spa by \u003cstrong\u003e10°C\u003c\/strong\u003e based on water volume. Real-world results vary, but this is handy for comparing heater output and expected heat-up speed.\u003c\/p\u003e\n\u003cstyle\u003e\n  .heatup-wrap { overflow-x: auto; -webkit-overflow-scrolling: touch; }\n  table.heatup-table { border-collapse: collapse; width: 100%; min-width: 980px; font-size: 14px; }\n  .heatup-table th, .heatup-table td { border: 1px solid #d9d9d9; padding: 8px 10px; text-align: center; white-space: nowrap; }\n  .heatup-table thead th { background: #E0F7FA; position: sticky; top: 0; z-index: 2; }\n  .heatup-table tbody tr:nth-child(even) td { background: #f9fbfc; }\n  .heatup-table th:first-child, .heatup-table td:first-child { text-align: left; font-weight: 700; position: sticky; left: 0; background: #ffffff; z-index: 1; }\n  .heatup-table thead th:first-child { z-index: 3; background: #E0F7FA; }\n  .heatup-note { margin-top: 10px; color: #b00020; font-size: 13px; }\n\u003c\/style\u003e\n\u003cdiv class=\"heatup-wrap\"\u003e\n\u003ctable class=\"heatup-table\" aria-label=\"Approximate time to raise water temperature by 10 degrees Celsius per heater by volume of water\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHeater\u003c\/th\u003e\n\u003cth\u003ekW*\u003c\/th\u003e\n\u003cth\u003e1,000 L\u003c\/th\u003e\n\u003cth\u003e5,000 L\u003c\/th\u003e\n\u003cth\u003e10,000 L\u003c\/th\u003e\n\u003cth\u003e15,000 L\u003c\/th\u003e\n\u003cth\u003e20,000 L\u003c\/th\u003e\n\u003cth\u003e25,000 L\u003c\/th\u003e\n\u003cth\u003e30,000 L\u003c\/th\u003e\n\u003cth\u003e40,000 L\u003c\/th\u003e\n\u003cth\u003e50,000 L\u003c\/th\u003e\n\u003cth\u003e60,000 L\u003c\/th\u003e\n\u003cth\u003e70,000 L\u003c\/th\u003e\n\u003cth\u003e80,000 L\u003c\/th\u003e\n\u003cth\u003e90,000 L\u003c\/th\u003e\n\u003cth\u003e100,000 L\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHX 70\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e45m\u003c\/td\u003e\n\u003ctd\u003e3h 45m\u003c\/td\u003e\n\u003ctd\u003e7h 15m\u003c\/td\u003e\n\u003ctd\u003e10h 45m\u003c\/td\u003e\n\u003ctd\u003e14h 30m\u003c\/td\u003e\n\u003ctd\u003e18h 15m\u003c\/td\u003e\n\u003ctd\u003e21h 45m\u003c\/td\u003e\n\u003ctd\u003e29h\u003c\/td\u003e\n\u003ctd\u003e36h 15m\u003c\/td\u003e\n\u003ctd\u003e43h 45m\u003c\/td\u003e\n\u003ctd\u003e50h 45m\u003c\/td\u003e\n\u003ctd\u003e58h\u003c\/td\u003e\n\u003ctd\u003e65h 30m\u003c\/td\u003e\n\u003ctd\u003e72h 45m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHX 120\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003ctd\u003e2h 15m\u003c\/td\u003e\n\u003ctd\u003e4h 30m\u003c\/td\u003e\n\u003ctd\u003e6h 45m\u003c\/td\u003e\n\u003ctd\u003e9h\u003c\/td\u003e\n\u003ctd\u003e11h 15m\u003c\/td\u003e\n\u003ctd\u003e13h 30m\u003c\/td\u003e\n\u003ctd\u003e17h 45m\u003c\/td\u003e\n\u003ctd\u003e22h 15m\u003c\/td\u003e\n\u003ctd\u003e26h 45m\u003c\/td\u003e\n\u003ctd\u003e31h 15m\u003c\/td\u003e\n\u003ctd\u003e35h 45m\u003c\/td\u003e\n\u003ctd\u003e40h 15m\u003c\/td\u003e\n\u003ctd\u003e44h 45m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJX 130\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003ctd\u003e2h 15m\u003c\/td\u003e\n\u003ctd\u003e4h 15m\u003c\/td\u003e\n\u003ctd\u003e6h 30m\u003c\/td\u003e\n\u003ctd\u003e8h 30m\u003c\/td\u003e\n\u003ctd\u003e10h 45m\u003c\/td\u003e\n\u003ctd\u003e12h 45m\u003c\/td\u003e\n\u003ctd\u003e17h\u003c\/td\u003e\n\u003ctd\u003e21h 15m\u003c\/td\u003e\n\u003ctd\u003e25h 30m\u003c\/td\u003e\n\u003ctd\u003e29h 45m\u003c\/td\u003e\n\u003ctd\u003e34h\u003c\/td\u003e\n\u003ctd\u003e38h 30m\u003c\/td\u003e\n\u003ctd\u003e42h 45m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJX 160\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e20m\u003c\/td\u003e\n\u003ctd\u003e1h 40m\u003c\/td\u003e\n\u003ctd\u003e3h 15m\u003c\/td\u003e\n\u003ctd\u003e4h 45m\u003c\/td\u003e\n\u003ctd\u003e6h 15m\u003c\/td\u003e\n\u003ctd\u003e8h\u003c\/td\u003e\n\u003ctd\u003e9h 30m\u003c\/td\u003e\n\u003ctd\u003e12h 45m\u003c\/td\u003e\n\u003ctd\u003e16h\u003c\/td\u003e\n\u003ctd\u003e19h 15m\u003c\/td\u003e\n\u003ctd\u003e22h 30m\u003c\/td\u003e\n\u003ctd\u003e25h 45m\u003c\/td\u003e\n\u003ctd\u003e29h\u003c\/td\u003e\n\u003ctd\u003e32h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"heatup-note\"\u003e\u003cstrong\u003eDisclaimer:\u003c\/strong\u003e This chart is a general guide only. Actual heating times vary depending on ambient temperature, water circulation, heater efficiency, pool cover use, wind, and heat loss. Do not rely on these figures for design, installation, or operational decisions. \u003cstrong\u003e*kW output ratings are a rough conversion.\u003c\/strong\u003e\u003c\/p\u003e","products":[{"product_id":"raypak-430-gas-pool-spa-heater","title":"Raypak 430 Gas Pool \u0026 Spa Heater - Domestic - ~94 kW Output - Natural Gas","description":"\u003ch3\u003eRaypak 430 Gas Pool \u0026amp; Spa Heater — Natural Gas\u003c\/h3\u003e\u003cp\u003eThe Raypak 430 produces \u003cstrong\u003e94 kW\u003c\/strong\u003e of output from a 420 MJ\/h natural gas input. Manufacturer model \u003cstrong\u003eP0430A-N\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e Natural Gas — model P0430A-N\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-lpg-gas-pool-spa-heater\"\u003eRaypak 430 — LPG (Propane)\u003c\/a\u003e. Commercial site? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-premium-430\"\u003eRaypak 430 Premium\u003c\/a\u003e adds bronze headers and full 3-year commercial parts cover.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0430A-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e420 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e94 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.77 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.13 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 745 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,780 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e420 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate metered volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10.9 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. Natural gas is billed in megajoules in Australia, so the MJ\/h figure above is the one your retailer charges against. The cubic-metre figure assumes 38.7 MJ\/m³, which varies a little between networks.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e94 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e37 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 14 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 51 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 28 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 6 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 43 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 57 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 25 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 h 40 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 54 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 h 22 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e34 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e27 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e38 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e19 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Gas suppliers increasingly deliver natural gas at 2.75 kPa. If the burner pressure is not adjusted down to the rating label figure at commissioning, the heater will be over-gassed and can be seriously damaged within minutes. This damage is not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 250 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 430 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-high-wind-top\"\u003eRaypak 430 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 90 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 430 Natural Gas, P0430A-N, Raypak 430 gas pool spa heater 94 kW, Raypak 430 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":41147543617725,"sku":"3611052","price":8371.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-430-gas-pool-spa-heater-domestic-94-kw-output-natural-426.webp?v=1785798067"},{"product_id":"raypak-350","title":"Raypak 350 Gas Pool \u0026 Spa Heater - Domestic - ~76 kW Output - Natural Gas","description":"\u003ch3\u003eRaypak 350 Gas Pool \u0026amp; Spa Heater — Natural Gas\u003c\/h3\u003e\u003cp\u003eThe Raypak 350 produces \u003cstrong\u003e76 kW\u003c\/strong\u003e of output from a 343 MJ\/h natural gas input. Manufacturer model \u003cstrong\u003eP0350A-N\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e Natural Gas — model P0350A-N\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-350-lpg\"\u003eRaypak 350 — LPG (Propane)\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0350A-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e343 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e76 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.77 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.13 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.3 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 655 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,675 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e343 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate metered volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8.9 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. Natural gas is billed in megajoules in Australia, so the MJ\/h figure above is the one your retailer charges against. The cubic-metre figure assumes 38.7 MJ\/m³, which varies a little between networks.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e76 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e46 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 32 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 4 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 49 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 35 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 7 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 39 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 h 43 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 h 14 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 h 46 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 h 18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e32 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e32 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e21 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Gas suppliers increasingly deliver natural gas at 2.75 kPa. If the burner pressure is not adjusted down to the rating label figure at commissioning, the heater will be over-gassed and can be seriously damaged within minutes. This damage is not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 225 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-350-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 350 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-350-high-wind-top\"\u003eRaypak 350 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 85 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 350 Natural Gas, P0350A-N, Raypak 350 gas pool spa heater 76 kW, Raypak 350 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":41147545747645,"sku":"3611050","price":8132.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-350-gas-pool-spa-heater-domestic-76-kw-output-natural-361.webp?v=1785797707"},{"product_id":"raypak-280","title":"Raypak 280 Gas Pool \u0026 Spa Heater - Domestic - ~62 kW Output - Natural Gas","description":"\u003ch3\u003eRaypak 280 Gas Pool \u0026amp; Spa Heater — Natural Gas\u003c\/h3\u003e\u003cp\u003eThe Raypak 280 produces \u003cstrong\u003e62 kW\u003c\/strong\u003e of output from a 278 MJ\/h natural gas input. Manufacturer model \u003cstrong\u003eP0280A-N\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e Natural Gas — model P0280A-N\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-lpg\"\u003eRaypak 280 — LPG (Propane)\u003c\/a\u003e. Commercial site? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-premium\"\u003eRaypak 280 Premium\u003c\/a\u003e adds bronze headers and full 3-year commercial parts cover.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0280A-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e278 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e62 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.77 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.13 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.6 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 570 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,685 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e278 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate metered volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.2 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. Natural gas is billed in megajoules in Australia, so the MJ\/h figure above is the one your retailer charges against. The cubic-metre figure assumes 38.7 MJ\/m³, which varies a little between networks.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e62 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e56 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 53 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 49 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 45 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 41 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 38 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 23 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 h 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 h 53 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 h 45 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Gas suppliers increasingly deliver natural gas at 2.75 kPa. If the burner pressure is not adjusted down to the rating label figure at commissioning, the heater will be over-gassed and can be seriously damaged within minutes. This damage is not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 200 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 280 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-high-wind-top\"\u003eRaypak 280 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 75 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 280 Natural Gas, P0280A-N, Raypak 280 gas pool spa heater 62 kW, Raypak 280 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":41147548926141,"sku":"3611048","price":7365.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-280-gas-pool-spa-heater-domestic-62-kw-output-natural-463.webp?v=1785797285"},{"product_id":"raypak-200","title":"Raypak 200 Gas Pool \u0026 Spa Heater - Domestic - ~44 kW Output - Natural Gas","description":"\u003ch3\u003eRaypak 200 Gas Pool \u0026amp; Spa Heater — Natural Gas\u003c\/h3\u003e\u003cp\u003eThe Raypak 200 produces \u003cstrong\u003e44 kW\u003c\/strong\u003e of output from a 196 MJ\/h natural gas input. Manufacturer model \u003cstrong\u003eP0200A-N\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e Natural Gas — model P0200A-N\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-lpg\"\u003eRaypak 200 — LPG (Propane)\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0200A-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e196 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e44 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.77 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.13 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.5 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 465 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e196 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate metered volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5.1 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. Natural gas is billed in megajoules in Australia, so the MJ\/h figure above is the one your retailer charges against. The cubic-metre figure assumes 38.7 MJ\/m³, which varies a little between networks.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e44 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e24 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 19 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 39 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 58 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 36 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 56 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 h 34 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 h 13 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 h 51 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 h 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e21 h 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e23 h 47 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 h 26 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e21 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Gas suppliers increasingly deliver natural gas at 2.75 kPa. If the burner pressure is not adjusted down to the rating label figure at commissioning, the heater will be over-gassed and can be seriously damaged within minutes. This damage is not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 175 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 200 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-high-wind-top\"\u003eRaypak 200 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 70 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 200 Natural Gas, P0200A-N, Raypak 200 gas pool spa heater 44 kW, Raypak 200 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":41147551744189,"sku":"3611046","price":7144.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-200-gas-pool-spa-heater-domestic-44-kw-output-natural-934.webp?v=1785797291"},{"product_id":"gas-heater-cooldown-control","title":"Gas Heater Run-on Controller - Cooldown Mode - Dontek H5RO","description":"\u003ch3\u003eGas Heater Run-on Controller - Cooldown Mode - Dontek H5RO\u003c\/h3\u003e\u003cp\u003eEssential gas heater pump run on timer for all gas heaters. Extends life of heaters and prevents issues with overheating. If you're experiencing overheating, F2 errors, High Limit Faults, etc, this might be exactly what you need. We recommend a run on timer for all gas heaters.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is a time-delay run on controller that allows a pool\/spa pump to continue running for a period of time in order to allow a Gas heater to cool down properly. Uncooled heaters fail earlier, and often have pipes collapse due to the boiling water left in the heater. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOne of the most common failures of gas heaters is constant overheating. Even when it doesn't cause errors such as the infamous \"F2\" error, the constant overheating and over-running dramatically shortens the life of several components of gas pool and spa heaters. \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Time Switch eliminates the problem of pounding and knocking due to overheated water, reduces scale and lime deposits, and extends the service life of the heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe H5RO controller operates a gas heater from a chlorinator timeclock (or other device). When the chlorinator (or other device) goes to switch off the pump, it shuts down the heater, while continuing to run the pump for a period of time. This is referred to as a Cool-Down Period.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan also be set up with a low-voltage switch to override and switch the pump \u0026amp; heater on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/AQUAHEAT-H5RO-rA.4.pdf?v=1612393836\" target=\"_blank\"\u003e\u003cspan\u003eInstallation \u0026amp; User Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e3-Year Return-to-Us Warranty against Defects.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eDontek H5RO \/ Dontek H5R0 \/ Dontek Hero \/  Run On Timer \/ Run-on Timer\u003c\/em\u003e\u003c\/p\u003e","brand":"Dontek","offers":[{"title":"Default Title","offer_id":42757068368,"sku":"RC 3611064","price":544.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/gas-heater-run-on-controller-cooldown-mode-dontek-h5ro-parts-563.webp?v=1757635945"},{"product_id":"raypak-280-premium","title":"Raypak 280 Premium Gas Pool \u0026 Spa Heater - Commercial - ~62 kW Output - Natural Gas","description":"\u003ch3\u003eRaypak 280 Premium Gas Pool \u0026amp; Spa Heater — Natural Gas\u003c\/h3\u003e\u003cp\u003eThe Raypak 280 Premium is the light commercial version of the 280, producing \u003cstrong\u003e62 kW\u003c\/strong\u003e of output from a 278 MJ\/h natural gas input. Manufacturer model \u003cstrong\u003ePC0280A-N\u003c\/strong\u003e. The Premium series adds all-bronze headers for greater temperature tolerance and corrosion resistance, plus a stainless steel base and combustion support — and carries full 3-year parts cover in commercial applications.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e Natural Gas — model PC0280A-N\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-premium-lpg\"\u003eRaypak 280 Premium — LPG (Propane)\u003c\/a\u003e. Domestic install? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280\"\u003eRaypak 280 Residential\u003c\/a\u003e has the same output at a lower price, with ProTek Shield anode protection.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePremium vs Residential — What You Actually Get\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll bronze headers\u003c\/strong\u003e instead of polymer — higher temperature tolerance and better corrosion resistance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStainless steel base and combustion support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 years parts cover in commercial use\u003c\/strong\u003e — Residential models are built for single family dwellings, not commercial sites\u003c\/li\u003e\n\u003cli\u003eNote: ProTek Shield is fitted to Residential models only. The Premium relies on its bronze headers instead.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service, not annual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePC0280A-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e278 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e62 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.77 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.13 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.6 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 570 × 650 mm — allow an extra 150 mm width for the header inlet and outlet couplings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,685 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBronze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e278 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate metered volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.2 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. Natural gas is billed in megajoules in Australia, so the MJ\/h figure above is the one your retailer charges against. The cubic-metre figure assumes 38.7 MJ\/m³, which varies a little between networks.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e62 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e56 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 53 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 49 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 45 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 41 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 38 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 23 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 h 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 h 53 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 h 45 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eAll bronze headers, stainless steel base and combustion support\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003cli\u003eOn Premium models the pressure switch is accessed from the return cover, opposite the water connection side — not the in\/out cover as on Residential models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Gas suppliers increasingly deliver natural gas at 2.75 kPa. If the burner pressure is not adjusted down to the rating label figure at commissioning, the heater will be over-gassed and can be seriously damaged within minutes. This damage is not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 200 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial sites:\u003c\/strong\u003e Rheem recommends building redundancy into the heating system so the pool stays in service if one heater goes down.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial application or single family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service by a qualified technician as a condition of warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 280 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-high-wind-top\"\u003eRaypak 280 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 75 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 280 Premium Natural Gas, PC0280A-N, Raypak 280 Premium gas pool spa heater 62 kW, Raypak 280 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":31487607832633,"sku":"PC0280","price":10186.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-280-premium-gas-pool-spa-heater-commercial-62-kw-output-natural-502.webp?v=1785794226"},{"product_id":"raypak-premium-430","title":"Raypak 430 Premium Gas Pool \u0026 Spa Heater - Commercial - ~94 kW Output - Natural Gas","description":"\u003ch3\u003eRaypak 430 Premium Gas Pool \u0026amp; Spa Heater — Natural Gas\u003c\/h3\u003e\u003cp\u003eThe Raypak 430 Premium is the light commercial version of the 430, producing \u003cstrong\u003e94 kW\u003c\/strong\u003e of output from a 420 MJ\/h natural gas input. Manufacturer model \u003cstrong\u003ePC0430A-N\u003c\/strong\u003e. The Premium series adds all-bronze headers for greater temperature tolerance and corrosion resistance, plus a stainless steel base and combustion support — and carries full 3-year parts cover in commercial applications.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e Natural Gas — model PC0430A-N\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-premium-430-lpg\"\u003eRaypak 430 Premium — LPG (Propane)\u003c\/a\u003e. Domestic install? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-gas-pool-spa-heater\"\u003eRaypak 430 Residential\u003c\/a\u003e has the same output at a lower price, with ProTek Shield anode protection.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePremium vs Residential — What You Actually Get\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll bronze headers\u003c\/strong\u003e instead of polymer — higher temperature tolerance and better corrosion resistance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStainless steel base and combustion support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 years parts cover in commercial use\u003c\/strong\u003e — Residential models are built for single family dwellings, not commercial sites\u003c\/li\u003e\n\u003cli\u003eNote: ProTek Shield is fitted to Residential models only. The Premium relies on its bronze headers instead.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service, not annual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePC0430A-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e420 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e94 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.77 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.13 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 745 × 650 mm — allow an extra 150 mm width for the header inlet and outlet couplings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,780 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBronze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e420 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate metered volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10.9 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. Natural gas is billed in megajoules in Australia, so the MJ\/h figure above is the one your retailer charges against. The cubic-metre figure assumes 38.7 MJ\/m³, which varies a little between networks.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e94 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e37 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 14 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 51 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 28 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 6 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 43 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 57 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 25 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 h 40 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 54 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 h 22 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e34 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e27 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e38 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e19 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eAll bronze headers, stainless steel base and combustion support\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003cli\u003eOn Premium models the pressure switch is accessed from the return cover, opposite the water connection side — not the in\/out cover as on Residential models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Gas suppliers increasingly deliver natural gas at 2.75 kPa. If the burner pressure is not adjusted down to the rating label figure at commissioning, the heater will be over-gassed and can be seriously damaged within minutes. This damage is not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 250 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial sites:\u003c\/strong\u003e Rheem recommends building redundancy into the heating system so the pool stays in service if one heater goes down.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial application or single family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service by a qualified technician as a condition of warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 430 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-high-wind-top\"\u003eRaypak 430 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 90 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 430 Premium Natural Gas, PC0430A-N, Raypak 430 Premium gas pool spa heater 94 kW, Raypak 430 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":42905604817085,"sku":"PC0430 Prem","price":10749.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-430-premium-gas-pool-spa-heater-commercial-94-kw-output-natural-121.webp?v=1785794829"},{"product_id":"sc-pt-460944","title":"Pentair MasterTemp 400HD Gas Heater - Natural","description":"\u003ch3\u003ePentair MasterTemp 400HD Gas Heater - Natural\u003c\/h3\u003e\u003cp\u003ePentair MasterTemp 400HD Gas Heater is a spa or pool heater component for replacing a matching heater, element or heater assembly. Match the part number, size and existing equipment details before ordering.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Pentair MasterTemp 400HD Gas Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e PT-460944\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e heater element or heater assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm product is correct before ordering. \u003ca href=\"https:\/\/heaterandspaparts.com.au\/pages\/contact-us\"\u003eContact us\u003c\/a\u003e if unsure.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCommon search terms: Pentair mastertemp 400hd gas heater, pt-460944.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":46981191598269,"sku":"PT-460944","price":9998.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/pentair-mastertemp-400hd-gas-heater-natural-250.webp?v=1782217043"},{"product_id":"sc-pt-460949","title":"Pentair MasterTemp 200HD Gas Heater - LPG","description":"\u003ch3\u003ePentair MasterTemp 200HD Gas Heater - LPG\u003c\/h3\u003e\u003cp\u003ePentair MasterTemp 200HD Gas Heater is a spa or pool heater component for replacing a matching heater, element or heater assembly. Match the part number, size and existing equipment details before ordering.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Pentair MasterTemp 200HD Gas Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e PT-460949\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e heater element or heater assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm product is correct before ordering. \u003ca href=\"https:\/\/heaterandspaparts.com.au\/pages\/contact-us\"\u003eContact us\u003c\/a\u003e if unsure.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCommon search terms: Pentair mastertemp 200hd gas heater, pt-460949.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":46981193007293,"sku":"PT-460949","price":8051.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/pentair-mastertemp-200hd-gas-heater-lpg-493.webp?v=1782217047"},{"product_id":"sc-pt-460946","title":"Pentair MasterTemp 200HD Gas Heater - Natural","description":"\u003ch3\u003ePentair MasterTemp 200HD Gas Heater - Natural\u003c\/h3\u003e\u003cp\u003ePentair MasterTemp 200HD Gas Heater is a spa or pool heater component for replacing a matching heater, element or heater assembly. Match the part number, size and existing equipment details before ordering.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Pentair MasterTemp 200HD Gas Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e PT-460946\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e heater element or heater assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm product is correct before ordering. \u003ca href=\"https:\/\/heaterandspaparts.com.au\/pages\/contact-us\"\u003eContact us\u003c\/a\u003e if unsure.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCommon search terms: Pentair mastertemp 200hd gas heater, pt-460946.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":46981193040061,"sku":"PT-460946","price":8051.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/pentair-mastertemp-200hd-gas-heater-natural-899.webp?v=1782217035"},{"product_id":"sc-pt-460945","title":"Pentair MasterTemp 300HD Gas Heater - Natural","description":"\u003ch3\u003ePentair MasterTemp 300HD Gas Heater - Natural\u003c\/h3\u003e\u003cp\u003ePentair MasterTemp 300HD Gas Heater is a spa or pool heater component for replacing a matching heater, element or heater assembly. Match the part number, size and existing equipment details before ordering.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Pentair MasterTemp 300HD Gas Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e PT-460945\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e heater element or heater assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm product is correct before ordering. \u003ca href=\"https:\/\/heaterandspaparts.com.au\/pages\/contact-us\"\u003eContact us\u003c\/a\u003e if unsure.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCommon search terms: Pentair mastertemp 300hd gas heater, pt-460945.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":46981193236669,"sku":"PT-460945","price":9363.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/pentair-mastertemp-300hd-gas-heater-natural-629.webp?v=1782217039"},{"product_id":"sc-pt-460947","title":"Pentair MasterTemp 400HD Gas Heater - LPG","description":"\u003ch3\u003ePentair MasterTemp 400HD Gas Heater - LPG\u003c\/h3\u003e\u003cp\u003ePentair MasterTemp 400HD Gas Heater is a spa or pool heater component for replacing a matching heater, element or heater assembly. Match the part number, size and existing equipment details before ordering.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Pentair MasterTemp 400HD Gas Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e PT-460947\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e heater element or heater assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm product is correct before ordering. \u003ca href=\"https:\/\/heaterandspaparts.com.au\/pages\/contact-us\"\u003eContact us\u003c\/a\u003e if unsure.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCommon search terms: Pentair mastertemp 400hd gas heater, pt-460947.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":46981193334973,"sku":"PT-460947","price":9522.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/pentair-mastertemp-400hd-gas-heater-lpg-319.webp?v=1782217041"},{"product_id":"sc-pt-460948","title":"Pentair MasterTemp 300HD Gas Heater - LPG","description":"\u003ch3\u003ePentair MasterTemp 300HD Gas Heater - LPG\u003c\/h3\u003e\u003cp\u003ePentair MasterTemp 300HD Gas Heater is a spa or pool heater component for replacing a matching heater, element or heater assembly. Match the part number, size and existing equipment details before ordering.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Pentair MasterTemp 300HD Gas Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e PT-460948\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e heater element or heater assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm product is correct before ordering. \u003ca href=\"https:\/\/heaterandspaparts.com.au\/pages\/contact-us\"\u003eContact us\u003c\/a\u003e if unsure.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCommon search terms: Pentair mastertemp 300hd gas heater, pt-460948.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":46981193433277,"sku":"PT-460948","price":8917.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/pentair-mastertemp-300hd-gas-heater-lpg-538.webp?v=1782217044"},{"product_id":"raypak-200-lpg","title":"Raypak 200 Gas Pool \u0026 Spa Heater - Domestic - ~41 kW Output - LPG (Propane)","description":"\u003ch3\u003eRaypak 200 Gas Pool \u0026amp; Spa Heater — LPG (Propane)\u003c\/h3\u003e\u003cp\u003eThe Raypak 200 produces \u003cstrong\u003e41 kW\u003c\/strong\u003e of output from a 185 MJ\/h lpg (propane) input. Manufacturer model \u003cstrong\u003eP0200A-P\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e LPG (Propane) — model P0200A-P\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200\"\u003eRaypak 200 — Natural Gas\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0200A-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLPG (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e185 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e41 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.75 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.5 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 465 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e185 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate LPG consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3.7 kg\/h  (7.3 L\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRun time per 45 kg cylinder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eapprox. 12 h 4 min at full fire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. LPG conversions use 49.6 MJ\/kg and 25.3 MJ\/L for propane. A single 45 kg cylinder will not keep this heater running for long — most installations of this size run twin cylinders with an automatic changeover regulator, or a bulk tank.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e41 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 25 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 50 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 40 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 h 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 21 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 h 11 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e19 h 51 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e22 h 41 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25 h 31 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e28 h 22 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e21 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Propane models must run on propane only. Propane\/butane mixtures such as automotive LPG are unsafe in this heater and will damage it. Burner pressure must be set to the rating label figure at commissioning — incorrect gas settings are not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 175 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 200 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-high-wind-top\"\u003eRaypak 200 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 70 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 200 LPG (Propane), P0200A-P, Raypak 200 gas pool spa heater 41 kW, Raypak 200 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":47149024837821,"sku":"3611047","price":7144.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-200-gas-pool-spa-heater-domestic-41-kw-output-lpg-propane-675.webp?v=1785797765"},{"product_id":"raypak-280-lpg","title":"Raypak 280 Gas Pool \u0026 Spa Heater - Domestic - ~58 kW Output - LPG (Propane)","description":"\u003ch3\u003eRaypak 280 Gas Pool \u0026amp; Spa Heater — LPG (Propane)\u003c\/h3\u003e\u003cp\u003eThe Raypak 280 produces \u003cstrong\u003e58 kW\u003c\/strong\u003e of output from a 261 MJ\/h lpg (propane) input. Manufacturer model \u003cstrong\u003eP0280A-P\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e LPG (Propane) — model P0280A-P\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280\"\u003eRaypak 280 — Natural Gas\u003c\/a\u003e. Commercial site? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-premium-lpg\"\u003eRaypak 280 Premium\u003c\/a\u003e adds bronze headers and full 3-year commercial parts cover.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0280A-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLPG (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e261 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e58 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.75 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.6 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 570 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,685 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e261 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate LPG consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5.3 kg\/h  (10.3 L\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRun time per 45 kg cylinder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eapprox. 8 h 33 min at full fire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. LPG conversions use 49.6 MJ\/kg and 25.3 MJ\/L for propane. A single 45 kg cylinder will not keep this heater running for long — most installations of this size run twin cylinders with an automatic changeover regulator, or a bulk tank.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e58 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 h 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 h 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 h 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 h 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 h 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Propane models must run on propane only. Propane\/butane mixtures such as automotive LPG are unsafe in this heater and will damage it. Burner pressure must be set to the rating label figure at commissioning — incorrect gas settings are not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 200 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 280 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-high-wind-top\"\u003eRaypak 280 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 75 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 280 LPG (Propane), P0280A-P, Raypak 280 gas pool spa heater 58 kW, Raypak 280 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":47149065830589,"sku":"3611049","price":7365.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-280-gas-pool-spa-heater-domestic-58-kw-output-lpg-propane-335.webp?v=1785797788"},{"product_id":"raypak-350-lpg","title":"Raypak 350 Gas Pool \u0026 Spa Heater - Domestic - ~72 kW Output - LPG (Propane)","description":"\u003ch3\u003eRaypak 350 Gas Pool \u0026amp; Spa Heater — LPG (Propane)\u003c\/h3\u003e\u003cp\u003eThe Raypak 350 produces \u003cstrong\u003e72 kW\u003c\/strong\u003e of output from a 323 MJ\/h lpg (propane) input. Manufacturer model \u003cstrong\u003eP0350A-P\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e LPG (Propane) — model P0350A-P\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-350\"\u003eRaypak 350 — Natural Gas\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0350A-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLPG (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e323 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e72 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.75 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.3 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 655 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,675 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e323 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate LPG consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6.5 kg\/h  (12.8 L\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRun time per 45 kg cylinder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eapprox. 6 h 55 min at full fire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. LPG conversions use 49.6 MJ\/kg and 25.3 MJ\/L for propane. A single 45 kg cylinder will not keep this heater running for long — most installations of this size run twin cylinders with an automatic changeover regulator, or a bulk tank.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e72 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e48 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 37 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 25 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 14 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 51 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 28 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 h 4 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 41 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 h 55 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 h 32 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 h 9 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e32 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e32 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e21 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Propane models must run on propane only. Propane\/butane mixtures such as automotive LPG are unsafe in this heater and will damage it. Burner pressure must be set to the rating label figure at commissioning — incorrect gas settings are not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 225 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-350-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 350 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-350-high-wind-top\"\u003eRaypak 350 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 85 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 350 LPG (Propane), P0350A-P, Raypak 350 gas pool spa heater 72 kW, Raypak 350 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":47149115048125,"sku":"3611051","price":8132.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-350-gas-pool-spa-heater-domestic-72-kw-output-lpg-propane-814.webp?v=1785797806"},{"product_id":"raypak-430-lpg-gas-pool-spa-heater","title":"Raypak 430 Gas Pool \u0026 Spa Heater - Domestic - ~88 kW Output - LPG (Propane)","description":"\u003ch3\u003eRaypak 430 Gas Pool \u0026amp; Spa Heater — LPG (Propane)\u003c\/h3\u003e\u003cp\u003eThe Raypak 430 produces \u003cstrong\u003e88 kW\u003c\/strong\u003e of output from a 396 MJ\/h lpg (propane) input. Manufacturer model \u003cstrong\u003eP0430A-P\u003c\/strong\u003e. Assembled in Australia by Rheem, with a cupro-nickel heat exchanger and ProTek Shield anode protection fitted as standard.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e LPG (Propane) — model P0430A-P\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-gas-pool-spa-heater\"\u003eRaypak 430 — Natural Gas\u003c\/a\u003e. Commercial site? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-premium-430-lpg\"\u003eRaypak 430 Premium\u003c\/a\u003e adds bronze headers and full 3-year commercial parts cover.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eP0430A-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLPG (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e396 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e88 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.75 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.07 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 745 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,780 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePolymer with ProTek Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e396 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate LPG consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8.0 kg\/h  (15.7 L\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRun time per 45 kg cylinder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eapprox. 5 h 38 min at full fire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. LPG conversions use 49.6 MJ\/kg and 25.3 MJ\/L for propane. A single 45 kg cylinder will not keep this heater running for long — most installations of this size run twin cylinders with an automatic changeover regulator, or a bulk tank.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e88 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 19 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 59 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 39 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 58 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 36 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 56 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 h 34 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 54 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 h 13 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e34 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e27 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e38 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e19 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek Shield\u003c\/a\u003e module protecting the cupro-nickel heat exchanger — standard on Residential 200, 280, 350 and 430. It is sacrificial, so it depletes in service and is replaced as a maintenance item.\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eRaypak Residential heaters now include a built-in \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e. Check its condition whenever the heater is serviced.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Propane models must run on propane only. Propane\/butane mixtures such as automotive LPG are unsafe in this heater and will damage it. Burner pressure must be set to the rating label figure at commissioning — incorrect gas settings are not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 250 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eResidential models are built for single family dwellings. For a commercial site choose a Premium model instead.\u003c\/li\u003e\n\u003cli\u003eExcludes the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-protek-sacrificial-anode\"\u003eProTek sacrificial anode\u003c\/a\u003e, which is a replaceable consumable.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003eAnnual service by a qualified technician is a condition of warranty and a gas authority requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 430 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-high-wind-top\"\u003eRaypak 430 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 90 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 430 LPG (Propane), P0430A-P, Raypak 430 gas pool spa heater 88 kW, Raypak 430 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":47149164757181,"sku":"3611053","price":8371.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-430-gas-pool-spa-heater-domestic-88-kw-output-lpg-propane-403.webp?v=1785797769"},{"product_id":"raypak-premium-430-lpg","title":"Raypak 430 Premium Gas Pool \u0026 Spa Heater - Commercial - ~88 kW Output - LPG (Propane)","description":"\u003ch3\u003eRaypak 430 Premium Gas Pool \u0026amp; Spa Heater — LPG (Propane)\u003c\/h3\u003e\u003cp\u003eThe Raypak 430 Premium is the light commercial version of the 430, producing \u003cstrong\u003e88 kW\u003c\/strong\u003e of output from a 396 MJ\/h lpg (propane) input. Manufacturer model \u003cstrong\u003ePC0430A-P\u003c\/strong\u003e. The Premium series adds all-bronze headers for greater temperature tolerance and corrosion resistance, plus a stainless steel base and combustion support — and carries full 3-year parts cover in commercial applications.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e LPG (Propane) — model PC0430A-P\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-premium-430\"\u003eRaypak 430 Premium — Natural Gas\u003c\/a\u003e. Domestic install? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-lpg-gas-pool-spa-heater\"\u003eRaypak 430 Residential\u003c\/a\u003e has the same output at a lower price, with ProTek Shield anode protection.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePremium vs Residential — What You Actually Get\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll bronze headers\u003c\/strong\u003e instead of polymer — higher temperature tolerance and better corrosion resistance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStainless steel base and combustion support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 years parts cover in commercial use\u003c\/strong\u003e — Residential models are built for single family dwellings, not commercial sites\u003c\/li\u003e\n\u003cli\u003eNote: ProTek Shield is fitted to Residential models only. The Premium relies on its bronze headers instead.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service, not annual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePC0430A-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLPG (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e396 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e88 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.75 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.07 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 745 × 650 mm — allow an extra 150 mm width for the header inlet and outlet couplings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,780 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBronze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e396 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate LPG consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8.0 kg\/h  (15.7 L\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRun time per 45 kg cylinder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eapprox. 5 h 38 min at full fire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. LPG conversions use 49.6 MJ\/kg and 25.3 MJ\/L for propane. A single 45 kg cylinder will not keep this heater running for long — most installations of this size run twin cylinders with an automatic changeover regulator, or a bulk tank.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e88 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 19 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h 59 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h 39 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h 58 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 36 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7 h 56 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e9 h 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 h 34 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e11 h 54 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e13 h 13 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e34 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e27 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e38 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e19 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eAll bronze headers, stainless steel base and combustion support\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003cli\u003eOn Premium models the pressure switch is accessed from the return cover, opposite the water connection side — not the in\/out cover as on Residential models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Propane models must run on propane only. Propane\/butane mixtures such as automotive LPG are unsafe in this heater and will damage it. Burner pressure must be set to the rating label figure at commissioning — incorrect gas settings are not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 250 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial sites:\u003c\/strong\u003e Rheem recommends building redundancy into the heating system so the pool stays in service if one heater goes down.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial application or single family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service by a qualified technician as a condition of warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 430 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-430-high-wind-top\"\u003eRaypak 430 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 90 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 430 Premium LPG (Propane), PC0430A-P, Raypak 430 Premium gas pool spa heater 88 kW, Raypak 430 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Heater and Spa Parts","offers":[{"title":"Default Title","offer_id":47149197721789,"sku":"PC0430 Prem-LPG","price":10749.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-430-premium-gas-pool-spa-heater-commercial-88-kw-output-lpg-propane-108.webp?v=1785794855"},{"product_id":"raypak-280-premium-lpg","title":"Raypak 280 Premium Gas Pool \u0026 Spa Heater - Commercial - ~58 kW Output - LPG (Propane)","description":"\u003ch3\u003eRaypak 280 Premium Gas Pool \u0026amp; Spa Heater — LPG (Propane)\u003c\/h3\u003e\u003cp\u003eThe Raypak 280 Premium is the light commercial version of the 280, producing \u003cstrong\u003e58 kW\u003c\/strong\u003e of output from a 261 MJ\/h lpg (propane) input. Manufacturer model \u003cstrong\u003ePC0280A-P\u003c\/strong\u003e. The Premium series adds all-bronze headers for greater temperature tolerance and corrosion resistance, plus a stainless steel base and combustion support — and carries full 3-year parts cover in commercial applications.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eWe keep these physically in stock for fast shipping or local pick-up, unlike most drop-shipping websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped Australia-wide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#E0F7FA;border:1px solid #bfeaf1;padding:14px 16px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFuel type:\u003c\/strong\u003e LPG (Propane) — model PC0280A-P\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eAlso available:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-premium\"\u003eRaypak 280 Premium — Natural Gas\u003c\/a\u003e. Domestic install? The \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-lpg\"\u003eRaypak 280 Residential\u003c\/a\u003e has the same output at a lower price, with ProTek Shield anode protection.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eWhy Buy From Us?\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak authorised dealer and warranty agent\u003c\/li\u003e\n\u003cli\u003eWe carry \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003emore Raypak gas heater spare parts\u003c\/a\u003e than anyone in Australia\u003c\/li\u003e\n\u003cli\u003eEx-manufacturer technicians on staff — over 20 years in gas pool and spa heating\u003c\/li\u003e\n\u003cli\u003eFastest Dispatch from our network.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePremium vs Residential — What You Actually Get\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll bronze headers\u003c\/strong\u003e instead of polymer — higher temperature tolerance and better corrosion resistance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStainless steel base and combustion support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 years parts cover in commercial use\u003c\/strong\u003e — Residential models are built for single family dwellings, not commercial sites\u003c\/li\u003e\n\u003cli\u003eNote: ProTek Shield is fitted to Residential models only. The Premium relies on its bronze headers instead.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service, not annual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications*\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePC0280A-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLPG (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e261 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e58 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOperating burner pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMinimum gas supply pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2.75 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eMain injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePilot injector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater flow, min \/ max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.6 \/ 6.9 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eDimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,055 × 570 × 650 mm — allow an extra 150 mm width for the header inlet and outlet couplings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIndoor flue diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOverall height, indoor config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,685 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeaders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBronze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCupro-nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectronic DSI — no standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e240 V AC, 10 A weatherproof GPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003e* Manufacturer figures vary slightly between the Raypak brochure and the installation manual. Figures shown here are taken from the Owner’s Guide \u0026amp; Installation Instructions.\u003c\/p\u003e\u003ch3\u003eGas Consumption\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eGas input at full fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e261 MJ\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eApproximate LPG consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5.3 kg\/h  (10.3 L\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRun time per 45 kg cylinder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eapprox. 8 h 33 min at full fire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFigures are at full fire. The heater only draws this while it is actually calling for heat, so daily usage depends on how far below set point the water sits, the weather, and whether a cover is fitted. LPG conversions use 49.6 MJ\/kg and 25.3 MJ\/L for propane. A single 45 kg cylinder will not keep this heater running for long — most installations of this size run twin cylinders with an automatic changeover regulator, or a bulk tank.\u003c\/p\u003e\u003ch3\u003eHeat-Up Time to Raise Water Temperature by 10 °C\u003c\/h3\u003e\u003cp\u003eCalculated from this model’s actual rated output of \u003cstrong\u003e58 kW\u003c\/strong\u003e.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eWater volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eTime for +10 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1,500 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 h 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 h 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e70,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 h 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16 h 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e90,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e18 h 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 h 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background:#FFF8E1;border:1px solid #f0e0a8;padding:12px 14px;margin:12px 0 0;border-radius:6px;font-size:13px;\"\u003e\n\u003cstrong\u003eThese times will vary — treat them as a best case.\u003c\/strong\u003e They are the pure thermodynamic figures: water volume × 4.186 kJ per kg per °C ÷ the heater’s rated output, with \u003cem\u003eno allowance for heat loss\u003c\/em\u003e. In the real world a pool or spa is losing heat the whole time you are adding it. Expect longer, sometimes much longer, depending on air temperature, wind, humidity, water surface area, and above all whether a cover is fitted. An uncovered pool in cold or windy weather can take well over double these times, and in extreme conditions may not reach the target at all. Use this table to compare models, not as a guarantee of performance on your site.\u003c\/div\u003e\u003ch3\u003eHeat-Up Performance — Manufacturer Figures\u003c\/h3\u003e\u003cp style=\"margin-bottom:6px;\"\u003e\u003cstrong\u003ePool temperature rise over 24 hours:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003ePool surface area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e60 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 m²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e14 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eSpa temperature rise per hour:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eSpa volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,000 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5,000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eRise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12 °C\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eRheem published figures for this model size. Based on outdoor installation, 2.2 km\/h average wind, 1.3 m water depth, pool cover fitted. Indoor installs run higher; uncovered or exposed pools run lower.\u003c\/p\u003e\u003ch3\u003eStandard Features\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eAll bronze headers, stainless steel base and combustion support\u003c\/li\u003e\n\u003cli\u003eCupro-nickel heat exchanger for corrosion resistance in chlorinated and salt water\u003c\/li\u003e\n\u003cli\u003eDigital thermostat with independent Pool and Spa set points\u003c\/li\u003e\n\u003cli\u003e7-day programmable time clock with four daily timer periods\u003c\/li\u003e\n\u003cli\u003eChild-lock function\u003c\/li\u003e\n\u003cli\u003eService code diagnostics\u003c\/li\u003e\n\u003cli\u003ePowder-coated heavy gauge metal casing\u003c\/li\u003e\n\u003cli\u003eExternal switch terminal for third-party automation and WiFi pool controls\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor or outdoor installation — outdoor configuration supplied as standard\u003c\/li\u003e\n\u003cli\u003eLeft or right hand water connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eImportant: When Replacing an Existing Raypak Heater\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eRaypak heaters no longer have a built-in valve actuator or pump control. If you are operating valve actuators or switching a pump, you will need a control system such as the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/dontek-aquatek?variant=41023899697341\" title=\"Dontek Aquatek Pool Controller with WiFi\"\u003eAquatek with WiFi\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBecause the heater has no pump control of its own, it cannot run the pump on after the burner shuts down. If your control system has no cool-down mode, fit a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003erun-on timer\u003c\/a\u003e — see accessories below.\u003c\/li\u003e\n\u003cli\u003eWe do not recommend the newer Raypak 280, 350 and 430 heaters be installed where 40 mm plumbing is used — flow characteristics have changed on the newer models.\u003c\/li\u003e\n\u003cli\u003eOn Premium models the pressure switch is accessed from the return cover, opposite the water connection side — not the in\/out cover as on Residential models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed installation only.\u003c\/strong\u003e Must be installed by a qualified gas fitter who issues a compliance certificate. Installation to AS\/NZS 5601.1, AS\/NZS 3500.4 and AS\/NZS 3000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas supply — read this.\u003c\/strong\u003e Propane models must run on propane only. Propane\/butane mixtures such as automotive LPG are unsafe in this heater and will damage it. Burner pressure must be set to the rating label figure at commissioning — incorrect gas settings are not covered by warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor:\u003c\/strong\u003e minimum 1,500 mm from any window or room ventilation opening, no obstructions above, level non-combustible base, not under eaves or pool decks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor:\u003c\/strong\u003e requires the indoor hood conversion kit and compliant 200 mm flueing. Minimum clearances on non-combustible surfaces — rear 150 mm, front 750 mm, water side 600 mm, non-water side 150 mm, above 1,200 mm. On combustible surfaces, rear and non-water side increase to 500 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind areas:\u003c\/strong\u003e a High Wind Top or induced draft fan may be needed. In constant high wind, site the heater at least 1 m from high vertical walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow switch:\u003c\/strong\u003e required if heater pipework sits more than 1,500 mm above or below pool water level (Raypak part AQ0200201).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorinators and dosing systems\u003c\/strong\u003e must feed downstream of the heater with an anti-siphon device fitted. Chemicals entering the heater directly will destroy the heat exchanger and void warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial sites:\u003c\/strong\u003e Rheem recommends building redundancy into the heating system so the pool stays in service if one heater goes down.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWater Balance — Warranty Critical\u003c\/h3\u003e\u003cp\u003eIncorrect water balance is the single most common cause of heat exchanger failure, and corrosive water voids the Rheem warranty. Target ranges:\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass pools, under 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eFibreglass spas, over 31 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u003cstrong\u003eOther pools \u0026amp; spas\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.3 – 7.4\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7.6 – 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTotal alkalinity (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120 – 150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e80 – 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCalcium hardness (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e200 – 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSalt (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFree chlorine (ppm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2 – 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLangelier Saturation Index\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eFree chlorine must not exceed 4 ppm. Free bromine must not exceed 5 ppm. Never add acid to the skimmer box — add small amounts spread across the pool surface.\u003c\/p\u003e\u003ch3\u003eController Service Codes\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePO\u003c\/strong\u003e — no mains power to the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO\u003c\/strong\u003e — insufficient water pressure, pump not running or pressure switch needs adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF1\u003c\/strong\u003e — wiring or electronics fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF2\u003c\/strong\u003e — main sensor open circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3\u003c\/strong\u003e — main sensor short circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF4\u003c\/strong\u003e — secondary sensor short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe heater also locks out on over-temperature if inlet water exceeds 45 °C. It must cool to roughly 35 °C before the red reset button will illuminate and reset — allow up to 4 hours.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial application or single family dwelling:\u003c\/strong\u003e 3 years parts, 1 year labour.\u003c\/li\u003e\n\u003cli\u003eWarranty does not cover incorrect gas settings, corrosive water, chemical damage, or installation by an unqualified person.\u003c\/li\u003e\n\u003cli\u003ePremium models require six-monthly service by a qualified technician as a condition of warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManuals \u0026amp; Documentation\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Pool_Spa_Gas_Heaters_-_Owners_Guide_Installation_Instructions_-_HASP.pdf?v=1785796654\"\u003eOwner’s Guide \u0026amp; Installation Instructions\u003c\/a\u003e — full 32-page manual covering installation, commissioning, controller programming, wiring diagrams and dimensional data\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/Raypak_Residential_Premium_Pool_Spa_Gas_Heaters_-_HASP.pdf?v=1785796446\"\u003eResidential \u0026amp; Premium Range Brochure\u003c\/a\u003e — model comparison, sizing guide and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak spare parts with exploded diagrams\u003c\/a\u003e — every serviceable part for the 200\/280\/350\/430, with diagrams to identify what you need. We stock more Raypak gas heater spare parts than anyone in Australia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor installation:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-draft-diverter-indoor-flue-kit-draught-stack\"\u003eRaypak 280 indoor draft diverter \/ draught stack\u003c\/a\u003e — required to convert this heater from its standard outdoor configuration to indoor. A Raypak heater must never be run indoors in outdoor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh wind locations:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-280-high-wind-top\"\u003eRaypak 280 High Wind Top\u003c\/a\u003e — these heaters are atmospherically vented, so gusty or exposed sites can upset combustion. The high wind top restores proper draw through the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended — run-on \/ cool-down:\u003c\/strong\u003e \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/gas-heater-cooldown-control\"\u003eDontek H5RO gas heater run-on controller\u003c\/a\u003e — we recommend one on any gas heater where the control system in place has no cool-down mode. It holds the filtration pump on after the burner shuts down so residual heat is carried out of the heat exchanger rather than left sitting in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-remote-control-thermostat\"\u003eIn-house remote control\u003c\/a\u003e — surface or flush mounted, 10 m, 20 m or 50 m cable\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/raypak-200-280-350-430-gas-pool-heater-spare-parts-with-diagram\"\u003eRaypak 200\/280\/350\/430 spare parts and exploded diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping\u003c\/h3\u003e\u003cp\u003eAt 75 kg this is a two-person lift. Someone may be required to help take the heater from the delivery truck if the carrier cannot provide a tailgate lifter.\u003c\/p\u003e\u003cp style=\"font-size:13px;color:#888;\"\u003eRaypak 280 Premium LPG (Propane), PC0280A-P, Raypak 280 Premium gas pool spa heater 58 kW, Raypak 280 replacement heater Australia. WWDG · SpaPro\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":47940973101245,"sku":"rp280premLPG","price":10186.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/raypak-280-premium-gas-pool-spa-heater-commercial-58-kw-output-lpg-propane-451.webp?v=1785794830"}],"url":"https:\/\/heaterandspaparts.com.au\/en-nz\/collections\/pool-spa-gas-heaters.oembed?page=2","provider":"Heater and Spa Parts","version":"1.0","type":"link"}