{"product_id":"astralpool-connect-10-universal-heater-controller","title":"NLA - Astralpool Connect 10 Universal Heater Control Kit - Gas Heater Hybrid Module - WWDG","description":"\u003ch3\u003eNLA - Astralpool Connect 10 Universal Heater Control Kit - Gas Heater Hybrid Module - WWDG\u003c\/h3\u003e\u003cp\u003e\u003cb\u003eNo Longer Available. No Alternative Available -- \u003c\/b\u003e\u003cb\u003eAstralpool Connect 10 Universal Heater Control Kit - Gas Heater Hybrid Module - \u003ca href=\"https:\/\/www.wwdg.org\" rel=\"noopener\" target=\"_blank\"\u003eWWDG\u003c\/a\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eArchived Information:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis kit allows almost any brand of gas heater or heat pump to be controlled by an \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/astralpool-viron-connect-10-pool-spa-control-system-with-options\"\u003eAstralpool Connect 10\u003c\/a\u003e Pool \u0026amp; Spa control system. Built by \u003ca href=\"https:\/\/www.wwdg.org\" rel=\"noopener\" target=\"_blank\"\u003eWWDG Technology\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eWorks with all \u003ca href=\"https:\/\/heaterandspaparts.com.au\/collections\/raypak-gas-heaters\"\u003eRaypak\u003c\/a\u003e, \u003ca href=\"https:\/\/heaterandspaparts.com.au\/collections\/pentair-gas-heaters\"\u003ePentair,\u003c\/a\u003e Hayward, \u003ca href=\"https:\/\/heaterandspaparts.com.au\/collections\/zodiac-gas-heaters\"\u003eZodiac\u003c\/a\u003e, \u003ca href=\"https:\/\/heaterandspaparts.com.au\/collections\/sensaheat-heat-pumps\"\u003eSensaheat\u003c\/a\u003e, \u003ca href=\"https:\/\/heaterandspaparts.com.au\/collections\/evoheat-heat-pumps\"\u003eEvoHeat\u003c\/a\u003e, Theralux, Reltech and most other pool or spa heaters utilising a flow or pressure switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes NOT suit older \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/hurlcon-genus-iv-pool-spa-control-system\"\u003eGenus \u003c\/a\u003econtrol systems.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #ff2a00; text-decoration-line: underline;\"\u003eImportant Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect 10 will need 1x \u003cem\u003eunused \u003c\/em\u003e240V controlled Channel (eg: 2, 3, 4, 5, 6, 7,or 8)\u003c\/li\u003e\n\u003cli\u003eTemp Sensor will need to be in the cold water side in the same line as the heater. Eg: If temp sensor is in a separate Solar Suction Line, it will need to be moved to what ever line the heater is in. We recommend Solar to have a separate solar controller, as the temp sensor cannot be in the solar water line.\u003c\/li\u003e\n\u003cli\u003eMust be fitted by a \u003cem\u003eQualified\u003c\/em\u003e person, experienced with Connect 10 controllers, as well as the heaters they're connecting to.\u003c\/li\u003e\n\u003cli\u003eGas heaters can only be worked on or modified by a licensed Type A gas service person.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eComplete Kit:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid Heater Module w\/ 3-pin Plug\u003c\/li\u003e\n\u003cli\u003eTemp Sensor Kit including Plumbing Fittings for Connect 10\u003c\/li\u003e\n\u003cli\u003e3m 'Figure-8' Control Cable w\/ Spade Terminals for Heater\u003c\/li\u003e\n\u003cli\u003ePart No: HUHC-01+520146_CK\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eStandalone Kit:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid Heater Module w\/ 3-pin Plug\u003c\/li\u003e\n\u003cli\u003eNote, you *will* need a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/connect-10-heater-sensor-kit?variant=41773464784\"\u003etemperature sensor\u003c\/a\u003e as per instructions below.\u003c\/li\u003e\n\u003cli\u003eThis kit is typically used as a replacement, or where you already have an in-line water temperature sensor\u003c\/li\u003e\n\u003cli\u003ePart No: HUHC-01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e--------------------------------------------------------------------------------\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eConnect 10 Setup:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eHardware:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFit temperature sensor kit inline, \u003cem\u003ebefore\u003c\/em\u003e the heater.\u003c\/li\u003e\n\u003cli\u003ePlug Temp Sensor into \"Water Temperature Plug\" in Connect 10\u003c\/li\u003e\n\u003cli\u003eIn the Connect 10 \"SYSTEM\/LOCAL\" jumper needs to be set to \"Local\"\u003c\/li\u003e\n\u003cli\u003eRun figure-8 cable to Gas Heater's pressure switch (Raypak, Pentair, etc) or to Heat Pump's Control connection. For gas heaters, simply unplug one spade terminal on pressure switch, plug \u003cem\u003eone\u003c\/em\u003e end of figure-8 wire to pressure switch, and then connect the other two loose wires together.\u003c\/li\u003e\n\u003cli\u003ePlug module into a controlled output on Connect 10 (usually Channel 8).\u003c\/li\u003e\n\u003cli\u003eSet Heater to ON and Maximum temperature (Connect 10 will control heater).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb\u003eSoftware: Note: \u003c\/b\u003e\u003c\/span\u003e\u003cem\u003e\u003cstrong\u003eConnect 10 software versions have different menus, wordings, etc. so there may be some variations to the instructions below. \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup 1:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eIn the Connect 10, go to \u003cstrong\u003eInstallation Setup\u003c\/strong\u003e \u0026amp; Enter your PIN.\u003c\/li\u003e\n\u003cli\u003eIn \u003cstrong\u003eSetup\u003c\/strong\u003e, under \u003cstrong\u003eHeater\u003c\/strong\u003e, go to \u003cstrong\u003eIs a Genus Heater installed?\u003c\/strong\u003e Select \u003cstrong\u003eNo\u003c\/strong\u003e (unless you \u003cem\u003edo\u003c\/em\u003e \u003cem\u003ealso\u003c\/em\u003e have an Astralpool heater).\u003c\/li\u003e\n\u003cli\u003eUnder \"\u003cstrong\u003eUse Connect temperature sensing?\u003c\/strong\u003e\" Select Yes.\u003c\/li\u003e\n\u003cli\u003eIn the \u003cstrong\u003eChannels\u003c\/strong\u003e setup select the Channel that will control power to this module. (Generally Channel 8).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eSetup 2: \u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eIn the Connect 10, go to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInstallation Setup\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; Enter your PIN.\u003c\/li\u003e\n\u003cli\u003eIn\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSetup\u003c\/strong\u003e, under\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHeater, \u003c\/strong\u003ego to\u003cstrong\u003e Temperature Control.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSelect\u003cstrong\u003e Display and control (Genus and Connect Inbuilt)\u003c\/strong\u003e, then click\u003cstrong\u003e Next\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eUnder \u003cstrong\u003eChoose primary heater type:\u003c\/strong\u003e select your primary heater.\u003c\/li\u003e\n\u003cli\u003eUnder Choose secondary heater type: select your secondary heater, then click \u003cstrong\u003eNext.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eClick through the menu and make necessary changes, and name your heater\/s.\u003c\/li\u003e\n\u003cli\u003eIn the \u003cstrong\u003eChannels\u003c\/strong\u003e setup select the Channel that will control power to this module. (Generally Channel 8).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eModule:\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePlug in module to the assigned output Channel set above (usually Channel 8).\u003c\/li\u003e\n\u003cli\u003eRun Twin Cable low-voltage cable to wire heater in series with the gas\/heat-pump heater's, pressure switch, flow switch or dedicated low-voltage switching circuit (fireman switch).\u003c\/li\u003e\n\u003cli\u003eDisconnect One Wire from Pressure\/Flow Switch \u0026amp; then Connect this Wire to One end of the Twin Cable from the Module.\u003c\/li\u003e\n\u003cli\u003eConnect the remaining Wire from the Twin Cable onto the Pressure-Flow Switch.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eYou may need to consult with the heater manufacturer to find the best way to connect. Generally the flow switch or pressure switch is fine to 'tap' into.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eThis work must be done by a qualified, experienced person. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/CONNECT_10_PRESSURE_SWITCH_HYBDRID_480x480.png?v=1605484978\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003eWater Rating:\u003c\/strong\u003e IP23\u003cbr\u003e\u003cstrong\u003eWarranty: \u003c\/strong\u003e12-months Return-to-Base\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e For Raypak heaters, we still recommend connecting the module to the pressure switch circuit. Using the External Switch terminal can cause confusion, as the heater may display a flame signal even when it is not running. When the module is connected to the pressure switch line as shown in the photo, the flame symbol will only appear when the heater is actually calling for heat.\u003c\/div\u003e\n\u003ch3\u003eManufacturer Catalogues, Diagrams \u0026amp; Part Numbers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNeed exploded views, spare part numbers, product numbers, diagrams, or more product information? See the manufacturer catalogues: \u003ca href=\"https:\/\/hasp.com.au\/pages\/Astralpool_Catalogue_2026\"\u003eAstralpool Catalogue 2026\u003c\/a\u003e | \u003ca href=\"https:\/\/hasp.com.au\/pages\/Zodiac_Catalogue_2026\"\u003eZodiac Catalogue 2026\u003c\/a\u003e \u003c\/strong\u003e\u003c\/p\u003e","brand":"Astralpool","offers":[{"title":"Connect 10 Hybrid Module w\/ Sensor Kit","offer_id":37180675129533,"sku":"HUHC-01 \u0026 520146 (include Info Sheet \u0026 Spade Terminals - 1F \u0026 1M)","price":361.0,"currency_code":"NZD","in_stock":false},{"title":"Hybrid Module - Standalone - Box","offer_id":37180675162301,"sku":"HUHC-01 (include Info Sheet \u0026 Spade Terminals - 1M \u0026 1F)","price":271.0,"currency_code":"NZD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/nla-astralpool-connect-10-universal-heater-control-kit-gas-hybrid-module-wwdg-w-sensor-pool-spa-169.webp?v=1780438747","url":"https:\/\/heaterandspaparts.com.au\/en-nz\/products\/astralpool-connect-10-universal-heater-controller","provider":"Heater and Spa Parts","version":"1.0","type":"link"}