{"product_id":"astralpool-p320-xt-impeller","title":"Astralpool Impeller Viron XT P320 40060X","description":"\u003c!-- HASP-FLP-1.0 | SKU 40060X | rule VIR-2.1 | canary: three-vane-echo --\u003e\n\u003ch3\u003eAstralpool Impeller Viron XT P320 40060X\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine Astralpool impeller, part number \u003cstrong\u003e40060X\u003c\/strong\u003e, for the \u003cstrong\u003eViron XT P320\u003c\/strong\u003e variable speed pool pump. It is approximately 133mm in diameter with a vane width of about 8.8mm. The same part number covers every generation of the XT P320 from the original release through to the current P320 C XT. It is \u003cem\u003enot\u003c\/em\u003e the impeller for the Viron eVo P320, and it is not the P520 impeller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe Viron XT Impeller Rule (rev. VIR-2.1)\u003c\/h3\u003e\n\u003cp\u003eAlmost every wrong impeller sent for this pump comes from ordering by the number on the pump rather than the letters after it. Several pumps carry \"P320\" on the badge and they do not share an impeller. Work through these four steps in order and finish on a measurement:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead the full model line on the pump badge, not just the number.\u003c\/strong\u003e You are looking for the letters immediately after the number: \u003cem\u003eXT\u003c\/em\u003e, \u003cem\u003eeVo\u003c\/em\u003e, or \u003cem\u003eC XT\u003c\/em\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf the badge says eVo, stop here.\u003c\/strong\u003e The eVo P320 uses the 11.5mm moulded small impeller shared with the CX320 \/ P280 \/ FX290 \/ CTX360 family — that is \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-p280-p320-fx290-e290\"\u003epart 40060F\u003c\/a\u003e, not this one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf the badge says XT or C XT, continue — the year does not matter.\u003c\/strong\u003e Isolate power, open the wet end, remove the impeller retaining bolt and withdraw the impeller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure the outside diameter of the old impeller across the widest point, and the width of the vane opening at the outer edge.\u003c\/strong\u003e The 40060X measures approximately \u003cstrong\u003e133mm across and 8.8mm at the vane\u003c\/strong\u003e. If the vane measures nearer 11.5mm you have the eVo-family impeller; if the whole impeller is noticeably larger, you have the P520.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eWorked Example\u003c\/h3\u003e\n\u003cp\u003eA Viron XT P320 fitted to a 48,000 litre pool at Carrum Downs in 2017 had lost roughly a third of its flow at full speed, though the motor still ran quietly and the basket and lid o-ring were clean. Stripping the wet end showed the impeller intact but with two vane tips worn back and a fine scoring ring where sand had passed through a failed multiport spider gasket. The old part measured 132.6mm across and 8.7mm at the vane opening — within tolerance of the 40060X figures — so the P320 impeller was the correct replacement, not the P520 and not the eVo part. A new mechanical seal went in at the same time, because the old seal faces had already been disturbed on removal.\u003c\/p\u003e\n\n\u003ch3\u003eWhich Impeller Do I Need?\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIf your pump badge reads\u003c\/th\u003e\n\u003cth\u003eAnd the old impeller measures\u003c\/th\u003e\n\u003cth\u003eYou need\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eViron XT P320, XT Series 2 P320, P320 C XT\u003c\/td\u003e\n\u003ctd\u003eapprox. 133mm dia, 8.8mm vane\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40060X — this product\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViron XT P520, XT Series 2 P520, P520 C XT\u003c\/td\u003e\n\u003ctd\u003enoticeably larger than 133mm\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-viron-xt-p520\"\u003eImpeller Viron XT P520 — 40060Z\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViron P320 eVo, P280, CX320, CTX360, FX290, E290\u003c\/td\u003e\n\u003ctd\u003e11.5mm vane, smaller body\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-p280-p320-fx290-e290\"\u003eImpeller P280 \/ P320 eVo — 40060F\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eEvery Model and Generation This Impeller Fits\u003c\/h3\u003e\n\u003cp\u003eAstralpool revised the Viron XT several times without ever changing the P320 impeller part number. If your pump is badged XT, the 40060X is correct regardless of its age or which of the revisions below it belongs to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P320 XT\u003c\/strong\u003e — original XT release, including all early-production units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P320 XT, pre-July 2018 wet end\u003c\/strong\u003e — wet end 40097, seal plate 40098, mechanical seal 75508. Impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P320 XT, July 2018 onwards wet end\u003c\/strong\u003e — revised wet end 40031 and seal plate 40030, mechanical seal 75509. Impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT Series 2 \/ XT MkII P320\u003c\/strong\u003e — revised controller and housing. Impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT P320C (Nov 2020 – June 2021)\u003c\/strong\u003e — impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT P320C (July 2021 onwards)\u003c\/strong\u003e — impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P320 C XT\u003c\/strong\u003e — the current model, which supersedes the earlier P320 XT variants. Impeller unchanged.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn short: the wet end, seal plate and mechanical seal were all revised over the life of the XT P320, but the impeller has stayed 40060X throughout. If you are ordering other parts at the same time, those \u003cem\u003eare\u003c\/em\u003e era-dependent and you will need to identify your pump's build date.\u003c\/p\u003e\n\n\u003ch3\u003eWhat This Impeller Does Not Fit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron eVo P320\u003c\/strong\u003e — despite the identical number on the badge, the eVo is a different pump generation with a different wet end. It takes the 11.5mm impeller shared with the CX320 \/ P280 \/ FX290 \/ CTX360 family: \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-p280-p320-fx290-e290\"\u003epart 40060F\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT P520 and P520 C XT\u003c\/strong\u003e — larger hydraulic package, larger impeller. Use \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-viron-xt-p520\"\u003e40060Z\u003c\/a\u003e instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P320 (original, pre-eVo)\u003c\/strong\u003e — carries its own separate parts breakdown. \u003ca href=\"mailto:info@hasp.com.au\"\u003eSend us a photo of your pump badge\u003c\/a\u003e and we will identify it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P600 and CTX400 series\u003c\/strong\u003e — different wet end and different part number entirely. \u003ca href=\"mailto:info@hasp.com.au\"\u003eContact us\u003c\/a\u003e with your model details.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHurlcon BX, TX and E-series pumps\u003c\/strong\u003e — pre-Viron wet ends, sized by motor. The 1.0HP versions take \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-p280-p320-fx290-e290\"\u003e40060F\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMeasurements \u0026amp; Fitting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutside diameter: approximately 133mm\u003c\/li\u003e\n\u003cli\u003eVane width at outer edge: approximately 8.8mm\u003c\/li\u003e\n\u003cli\u003eRetained by impeller retaining bolt \u003cstrong\u003e78187\u003c\/strong\u003e with o-ring \u003cstrong\u003e78711\u003c\/strong\u003e — inspect both on removal and replace if the o-ring is flattened or the bolt is corroded\u003c\/li\u003e\n\u003cli\u003eMatching mechanical seal: 75509 on current and post-2018 pumps, 75508 on the earliest XT builds\u003c\/li\u003e\n\u003cli\u003eMatching diffuser: \u003cstrong\u003e40071A\u003c\/strong\u003e (XT P320). The XT P520 takes 40071B — do not mix them\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSymptoms of a Failed or Worn Impeller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotor runs at normal speed and normal noise, but flow and filter pressure are both down\u003c\/li\u003e\n\u003cli\u003ePump takes far longer to prime, or will not hold prime, with no air leak found on the suction side\u003c\/li\u003e\n\u003cli\u003eGrinding, rattling or a rhythmic knock from the wet end\u003c\/li\u003e\n\u003cli\u003ePump humming but not turning — debris jammed in the impeller is a listed cause in the Astralpool troubleshooting guide, often after the hair and lint basket has split and allowed debris through\u003c\/li\u003e\n\u003cli\u003eController showing the \u003cstrong\u003eHI A\u003c\/strong\u003e over-current fault — Astralpool lists \"wrong impeller fitted\" as one of the causes, which is exactly what happens when a P520 impeller ends up on a P320\u003c\/li\u003e\n\u003cli\u003eVisible debris packed into the vane passages, or vane tips worn back and rounded\u003c\/li\u003e\n\u003cli\u003eCracked or spun hub after the pump has run dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cp\u003eReplace the impeller when the vanes are worn, chipped or cracked, when the hub has spun, or when the pump has run dry and the plastic has distorted. Blocked vanes can often be cleared rather than replaced — check that first. Because the mechanical seal is disturbed whenever the impeller comes off, we recommend fitting a new \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/3-4-mechanical-seal\"\u003emechanical seal\u003c\/a\u003e at the same time rather than reusing a seal whose faces have been separated.\u003c\/p\u003e\n\n\u003ch3\u003ePart Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40060X\u003c\/strong\u003e — Astralpool impeller, Viron XT P320, all generations (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40060Z\u003c\/strong\u003e — Astralpool impeller, Viron XT P520 (\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-viron-xt-p520\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40060F\u003c\/strong\u003e — Astralpool impeller, P320 eVo \/ P280 \/ CTX360 \/ FX290 \/ E290 (\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/impeller-p280-p320-fx290-e290\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78187\u003c\/strong\u003e — impeller retaining bolt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78711\u003c\/strong\u003e — impeller retaining bolt o-ring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e75509\u003c\/strong\u003e — mechanical seal, current \/ post-2018 pumps (\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/3-4-mechanical-seal\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e75508\u003c\/strong\u003e — mechanical seal, earliest XT builds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40071A\u003c\/strong\u003e — diffuser, XT P320 (40071B for XT P520)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78104\u003c\/strong\u003e — diffuser o-ring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40065\u003c\/strong\u003e — pump basket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40089\u003c\/strong\u003e — lid complete with o-ring (\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/complete-lid-assembly-for-astralpool-hurlcon-pumps-ctx-cx-tx-e-viron-xt-also-aquatight\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e70006\u003c\/strong\u003e — lid o-ring (\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/lid-o-ring-for-astralpool-hurlcon-pumps-ctx-cx-tx\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40097 \/ 40031\u003c\/strong\u003e — pump wet end, pre- and post-July 2018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40098 \/ 40030\u003c\/strong\u003e — seal plate, pre- and post-July 2018\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 40060X fit a Viron eVo P320?\u003c\/strong\u003e\u003cbr\u003eNo. The eVo P320 is a different pump generation and uses part 40060F, the 11.5mm impeller shared with the CX320, P280, CTX360 and FX290 pumps. Only the XT and C XT versions of the P320 take the 40060X.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this fit older Viron XT P320 pumps?\u003c\/strong\u003e\u003cbr\u003eYes. The impeller part number has never changed across the life of the XT P320. It covers the original XT, the pre-2018 and post-2018 wet end revisions, the XT Series 2, the P320C and the current P320 C XT.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 40060X and 40060Z?\u003c\/strong\u003e\u003cbr\u003e40060X is the P320 impeller and 40060Z is the P520 impeller. The P520 impeller is physically larger because the P520 is a higher flow pump. They are not interchangeable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the impeller held on?\u003c\/strong\u003e\u003cbr\u003eThe Viron XT impeller is secured by a retaining bolt, part 78187, with an o-ring, part 78711. Remove the bolt before attempting to withdraw the impeller, and inspect the o-ring while it is apart.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a new mechanical seal when I replace the impeller?\u003c\/strong\u003e\u003cbr\u003eWe recommend it. The mechanical seal is split apart as soon as the impeller comes off, and reused seal faces are the most common cause of a leak after an impeller change.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy pump runs but flow has dropped — is the impeller the cause?\u003c\/strong\u003e\u003cbr\u003ePossibly, but check the easy items first: skimmer and pump baskets, lid o-ring, suction blockages and a dirty filter. If those are clear and the motor is running at full speed, a worn or blocked impeller is the next thing to inspect.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy controller is showing HI A — can the impeller cause that?\u003c\/strong\u003e\u003cbr\u003eYes. Astralpool lists a wrong impeller being fitted as one of the causes of the HI A over-current fault, along with worn bearings or seal. If someone has previously fitted a P520 impeller to a P320, this is a common result.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Astralpool part?\u003c\/strong\u003e\u003cbr\u003eYes. We are an authorised Astralpool and Fluidra dealer and warranty agent, and this is the genuine 40060X impeller.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer Catalogues, Diagrams \u0026amp; Part Numbers\u003c\/h3\u003e\n\u003cp\u003eNeed exploded views, spare part numbers, product numbers or diagrams? See the manufacturer catalogue: \u003ca href=\"https:\/\/hasp.com.au\/pages\/Astralpool_Catalogue_2026\"\u003eAstralpool Catalogue 2026\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e confirm this part is correct for your pump. Use the catalogue above, seek professional assistance, or \u003ca href=\"mailto:info@hasp.com.au\"\u003econtact us\u003c\/a\u003e with photos of your existing part, model details, serial numbers and any labels. As with all products, this must be diagnosed and fitted by a qualified and experienced person.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eCommon search terms: Astralpool 40060X, Viron XT P320 impeller, Astral P320XT impeller, Viron P320C impeller, Hurlcon Viron P320 impeller, Viron XT Series 2 impeller, Viron variable speed pump impeller replacement.\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- HASP-FLP-1.0 end | canary: three-vane-echo --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Does the 40060X fit a Viron eVo P320?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The eVo P320 is a different pump generation and uses part 40060F, the 11.5mm impeller shared with the CX320, P280, CTX360 and FX290 pumps. Only the XT and C XT versions of the P320 take the 40060X.\"}},{\"@type\":\"Question\",\"name\":\"Does this fit older Viron XT P320 pumps?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The impeller part number has never changed across the life of the XT P320. It covers the original XT, the pre-2018 and post-2018 wet end revisions, the XT Series 2, the P320C and the current P320 C XT.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between 40060X and 40060Z?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"40060X is the P320 impeller and 40060Z is the P520 impeller. The P520 impeller is physically larger because the P520 is a higher flow pump. They are not interchangeable.\"}},{\"@type\":\"Question\",\"name\":\"How is the impeller held on?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The Viron XT impeller is secured by a retaining bolt, part 78187, with an o-ring, part 78711. Remove the bolt before attempting to withdraw the impeller, and inspect the o-ring while it is apart.\"}},{\"@type\":\"Question\",\"name\":\"Do I need a new mechanical seal when I replace the impeller?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"We recommend it. The mechanical seal is split apart as soon as the impeller comes off, and reused seal faces are the most common cause of a leak after an impeller change.\"}},{\"@type\":\"Question\",\"name\":\"My pump runs but flow has dropped - is the impeller the cause?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Possibly, but check the easy items first: skimmer and pump baskets, lid o-ring, suction blockages and a dirty filter. If those are clear and the motor is running at full speed, a worn or blocked impeller is the next thing to inspect.\"}},{\"@type\":\"Question\",\"name\":\"My controller is showing HI A - can the impeller cause that?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Astralpool lists a wrong impeller being fitted as one of the causes of the HI A over-current fault, along with worn bearings or seal. If someone has previously fitted a P520 impeller to a P320, this is a common result.\"}},{\"@type\":\"Question\",\"name\":\"Is this a genuine Astralpool part?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. We are an authorised Astralpool and Fluidra dealer and warranty agent, and this is the genuine 40060X impeller.\"}}]},{\"@type\":\"HowTo\",\"name\":\"The Viron XT Impeller Rule (rev. VIR-2.1)\",\"description\":\"How to confirm whether your Astralpool Viron pump takes the 40060X P320 impeller.\",\"step\":[{\"@type\":\"HowToStep\",\"name\":\"Read the full model line\",\"text\":\"Read the full model line on the pump badge, not just the number. Look for the letters immediately after the number: XT, eVo, or C XT.\"},{\"@type\":\"HowToStep\",\"name\":\"Rule out the eVo\",\"text\":\"If the badge says eVo, stop. The eVo P320 uses the 11.5mm moulded small impeller shared with the CX320, P280, FX290 and CTX360 family, which is part 40060F.\"},{\"@type\":\"HowToStep\",\"name\":\"Remove the impeller\",\"text\":\"If the badge says XT or C XT the year does not matter. Isolate power, open the wet end, remove the impeller retaining bolt and withdraw the impeller.\"},{\"@type\":\"HowToStep\",\"name\":\"Measure\",\"text\":\"Measure the outside diameter across the widest point and the vane width at the outer edge. The 40060X measures approximately 133mm across and 8.8mm at the vane. If the vane measures nearer 11.5mm you have the eVo-family impeller; if the whole impeller is noticeably larger, you have the P520.\"}]}]}\n\u003c\/script\u003e","brand":"Astralpool","offers":[{"title":"Default Title","offer_id":43705883197629,"sku":"40060X","price":95.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/astralpool-impeller-viron-xt-p320-40060x-pool-pump-parts-452.webp?v=1784680209","url":"https:\/\/heaterandspaparts.com.au\/en-nz\/products\/astralpool-p320-xt-impeller","provider":"Heater and Spa Parts","version":"1.0","type":"link"}