{"product_id":"hurlcon-astralpool-hx-jx-gas-conversion","title":"Astralpool HX, JX Gas Conversion Kits","description":"\u003ch3\u003eAstralpool HX, JX Gas Conversion Kits\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHurlcon \/ Astralpool HX, JX \u0026amp; WX Gas Conversion Kits\u003c\/strong\u003e to convert selected heaters from \u003cstrong\u003eNatural Gas to LPG \/ Propane\u003c\/strong\u003e or from \u003cstrong\u003eLPG \/ Propane to Natural Gas\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eYou will need to know which gas valve you have before choosing a kit from this page. \u003c\/span\u003e\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003ePlease read listing entirely!\u003c\/span\u003e\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese conversion kits suit many popular \u003cstrong\u003eHurlcon and Astralpool gas spa and pool heaters\u003c\/strong\u003e, including selected versions of the \u003cstrong\u003eHX 70, HX 120, HX 150, JX 130, JX 160\u003c\/strong\u003e and \u003cstrong\u003eWX\u003c\/strong\u003e models. If your heater uses the same model family but has a different gas valve, compliance version, or production series, the exact kit required can differ.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255); text-decoration: underline;\"\u003eChoosing the correct kit:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStep 1. Confirm the exact heater model.\u003c\/strong\u003e\u003cbr\u003eCheck the model from the \u003cstrong\u003eheater data plate \/ compliance label\u003c\/strong\u003e. Do not rely only on appearance, because similar looking heaters can use different internals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 2. Confirm the current gas type.\u003c\/strong\u003e\u003cbr\u003eCheck whether the heater is currently set up for \u003cstrong\u003eNatural Gas\u003c\/strong\u003e or \u003cstrong\u003eLPG \/ Propane\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 3. Identify the gas valve fitted.\u003c\/strong\u003e\u003cbr\u003eThis is critical. Many later heaters use a \u003cstrong\u003eTechrite\u003c\/strong\u003e gas valve (since around 2016), while many earlier heaters used \u003cstrong\u003eHoneywell, White Rodgers\u003c\/strong\u003e or other older valve types. On older units, your gasfitter may need to remove a panel to confirm the valve before the correct kit can be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 4. Match the kit to both the heater and valve type.\u003c\/strong\u003e\u003cbr\u003eThe correct kit depends on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe exact heater model,\u003c\/li\u003e\n\u003cli\u003ethe gas type you are converting \u003cem\u003efrom\u003c\/em\u003e and \u003cem\u003eto\u003c\/em\u003e,\u003c\/li\u003e\n\u003cli\u003ethe gas valve fitted now,\u003c\/li\u003e\n\u003cli\u003eand sometimes the production era \/ compliance version of the heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you are unsure, send us the \u003cstrong\u003eheater model details and a clear photo of the gas valve label\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eBefore ordering:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the \u003cstrong\u003eheater model\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm the \u003cstrong\u003ecurrent gas type\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm the \u003cstrong\u003egas valve brand \/ type\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eHave your installer verify the heater data plate and valve details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGas appliance work is not DIY.\u003c\/strong\u003e\u003c\/span\u003e This kit must only be fitted, tested and commissioned by a \u003cstrong\u003elicensed gasfitter \/ authorised person\u003c\/strong\u003e. Burner pressure must be checked with a \u003cstrong\u003emanometer\u003c\/strong\u003e at the gas valve test point, gas tightness must be confirmed, and the heater must be tested for correct operation before being returned to service.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eWhat this kit is for:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eIf you have an existing Hurlcon or Astralpool gas heater and need to change the heater from one gas type to the other, this kit provides the parts normally required for a proper conversion. Depending on the heater model and the gas valve currently fitted, this may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emain burner injectors \/ jets for the required gas type,\u003c\/li\u003e\n\u003cli\u003eregulator spring,\u003c\/li\u003e\n\u003cli\u003econversion \/ compliance labelling,\u003c\/li\u003e\n\u003cli\u003eand on some older heaters, a \u003cstrong\u003ereplacement gas valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is commonly required when a heater is being moved to a site with a different gas supply, when replacing an older heater setup, or where an installer needs to change an existing unit from \u003cstrong\u003eNG to LPG\u003c\/strong\u003e or \u003cstrong\u003eLPG to NG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eSuits these heater families:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHX Series\u003c\/strong\u003e including HX70 and HX120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJX Series\u003c\/strong\u003e including JX130 and JX160\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSelected WX models\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSome related Hurlcon \/ Astralpool variants using the same heater family platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHurlcon gas heaters later continued under the \u003cstrong\u003eAstralpool\u003c\/strong\u003e name, and the HX, WX and JX families remain among the most common Hurlcon \/ Astralpool gas heater ranges seen in Australia.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eWhat is included:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor heaters already fitted with a Techrite gas valve\u003c\/strong\u003e, the kit includes the \u003cstrong\u003ecorrect injectors, regulator spring and required labelling\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor heaters fitted with older Honeywell, White Rodgers or similar valves\u003c\/strong\u003e, the correct kit includes a \u003cstrong\u003ereplacement Techrite gas valve\u003c\/strong\u003e as well as the \u003cstrong\u003einjectors, regulator spring and labelling\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKit contents can vary depending on the exact heater and gas valve combination, so the installer should always compare the supplied parts with the heater being converted before starting work.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e\u003cspan\u003eImportant Installation Notes:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eYour gasfitterer is required to isolate gas and power, remove access panels, remove the burner assembly or injector manifold as required, change injectors, change spring or valve where applicable, leak test the system, then commission and adjust burner pressure using a manometer. On some versions, replacing an older valve can also mean minor changes or careful re-alignment of the internal gas pipework and fittings so the replacement valve seats correctly. All internal shields and panels must be refitted correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Some internal copper gas pipe may need to be adjusted or modified to suit new Techrite gas valve.\u003c\/p\u003e\n\u003cp\u003eComes with Spare Injector Nozzles -- Inspect each nozzle for correct hole size or blockage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not a trial-fit product.\u003c\/strong\u003e It is a gas conversion component set that must be selected correctly and installed by a qualified person who can identify the heater version and gas valve before ordering and fitting.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255); text-decoration: underline;\"\u003eNominal burner pressure reference guide:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe table below is provided as a \u003cstrong\u003egeneral reference guide only\u003c\/strong\u003e for common HX and JX models. \u003cstrong\u003eActual required pressure may differ\u003c\/strong\u003e depending on the exact heater, gas valve fitted, compliance version, appliance labelling, and conversion instructions applicable to that unit. Your installer must always refer to the \u003cstrong\u003eheater data plate, conversion instructions and labelling on the actual appliance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNatural Gas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLPG \/ Propane\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHX 70\u003c\/td\u003e\n\u003ctd\u003e1.0 kPa\u003c\/td\u003e\n\u003ctd\u003e2.62 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHX 120\u003c\/td\u003e\n\u003ctd\u003e0.92 kPa\u003c\/td\u003e\n\u003ctd\u003e2.62 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJX 130\u003c\/td\u003e\n\u003ctd\u003e0.92 kPa\u003c\/td\u003e\n\u003ctd\u003e2.60 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJX 160\u003c\/td\u003e\n\u003ctd\u003e0.88 kPa\u003c\/td\u003e\n\u003ctd\u003e2.60 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eImportant: This table is a guide only. It must not be relied on instead of the heater’s own labelling, data plate, or the instructions supplied for that heater and conversion kit.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eWhy valve type matters:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eMany wrong orders happen because people identify the heater model correctly but do \u003cstrong\u003enot\u003c\/strong\u003e identify the gas valve. That is where problems start. A later heater with a \u003cstrong\u003eTechrite\u003c\/strong\u003e valve may only need injectors, spring and labelling. An earlier unit with a \u003cstrong\u003eHoneywell\u003c\/strong\u003e, \u003cstrong\u003eWhite Rodgers\u003c\/strong\u003e or another older valve requires a different conversion approach, including a replacement gas valve. That is why the valve type must be confirmed before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255); text-decoration: underline;\"\u003eCommon search terms this product suits\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHurlcon HX70 gas conversion kit\u003c\/li\u003e\n\u003cli\u003eHurlcon HX120 LPG conversion\u003c\/li\u003e\n\u003cli\u003eAstralpool JX130 natural gas to LPG kit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHurlcon WX gas conversion kit\u003c\/li\u003e\n\u003cli\u003eTechrite gas valve conversion kit\u003c\/li\u003e\n\u003cli\u003eHoneywell gas valve Astralpool conversion\u003c\/li\u003e\n\u003cli\u003eWhite Rodgers Hurlcon gas conversion kit\u003c\/li\u003e\n\u003cli\u003eAstralpool heater NG to LPG\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255); text-decoration: underline;\"\u003eImportant disclaimer:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThis product is for use by qualified persons only. All gas work must comply with applicable installation instructions, local gas regulations, and relevant Australian \/ New Zealand standards. Pressure settings and final commissioning must always be confirmed on the actual appliance being converted.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eGas Conversion Kits for Hurlcon Astralpool HX70, HX120, HX150, JX130, JX160 and selected WX Gas Heaters. Converts Natural Gas to LPG \/ Propane or LPG \/ Propane to Natural Gas depending on the option selected.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eManufacturer Catalogues, Diagrams \u0026amp; Part Numbers\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eNeed exploded views, spare part numbers, product numbers, diagrams, or more product information? See the manufacturer catalogues:\n \u003ca href=\"https:\/\/hasp.com.au\/pages\/Astralpool_Catalogue_2026\"\u003eAstralpool Catalogue 2026\u003c\/a\u003e | \u003ca href=\"https:\/\/hasp.com.au\/pages\/Zodiac_Catalogue_2026\"\u003eZodiac Catalogue 2026\u003c\/a\u003e\n\u003c\/strong\u003e\u003c\/p\u003e","brand":"Astralpool","offers":[{"title":"Techrite - has TECHRITE on label (usually Heaters since 2017) \/ LPG (Propane)","offer_id":42810032193725,"sku":"10346","price":189.0,"currency_code":"NZD","in_stock":true},{"title":"All other valves - Honeywell\/White Rogers (most heaters before 2017) \/ LPG (Propane)","offer_id":46224684482749,"sku":"10356 + 477143","price":1048.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/astralpool-hx-jx-gas-conversion-kits-heater-parts-244.webp?v=1779181513","url":"https:\/\/heaterandspaparts.com.au\/en-nz\/products\/hurlcon-astralpool-hx-jx-gas-conversion","provider":"Heater and Spa Parts","version":"1.0","type":"link"}