{"product_id":"hurlcon-astralpool-raypak-gas-valve","title":"Astralpool Hurlcon Astralpool Gas Regulator Valve for HX 70, HX 120, JX 130, JX 160 and WX Gas Heaters","description":"\u003ch3\u003eAstralpool Hurlcon Astralpool Gas Regulator Valve for HX 70, HX 120, JX 130, JX 160 and WX Gas Heaters\u003c\/h3\u003e\u003cp\u003eGas Valve for Astralpool \u0026amp; Hurlcon and HX70, HX120, HX150, JX130, JX160, and WX (Wilton) gas spa heaters. May also suit Minimax 70, 120, 150, MM heaters, and Hurlcon Hendy H Boilers. Does not suit MX gas heaters.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"title_desc_products_s\"\u003e\u003cspan style=\"color: #000000;\"\u003eImages show the Honeywell, White Rogers and Techrite gas valves used in these heaters. The black Techrite version now supersedes \u003cem\u003eall \u003c\/em\u003eearlier\u003cem\u003e \u003c\/em\u003eHoneywell \u0026amp; White Rogers gas valves.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTechrite CV983 Gas Valve Regulator for Hurlcon and Astralpool HX70, HX120, JX130, JX160, and WX Wilton gas spa heaters. May also suit older Minimax MM heaters, and Hurlcon Hendy H Boilers. This is the Techrite version that supersedes all previous gas valves from Honeywell and White Rogers.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eImportant Notes:\u003c\/span\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation of these valves must be performed by authorised persons and must be in compliance with gas installation codes and any local authority regulations.\u003c\/li\u003e\n\u003cli\u003eNote in older heaters with White Rogers and Honeywell gas valves, some internal copper bending or minor modification may be necessary when retrofitting this Techrite valve.\u003c\/li\u003e\n\u003cli\u003eGas valve will require pressure adjustments once fitted.\u003c\/li\u003e\n\u003cli\u003eComes as Natural Gas valve. For LPG use, purchase \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/hurlcon-astralpool-hx-jx-gas-conversion?variant=42810032193725\" rel=\"noopener\" target=\"_blank\"\u003ethe conversion kit here\u003c\/a\u003e seperately.\u003c\/li\u003e\n\u003cli\u003eIf gas valve does not open after installation, swap the Active \u0026amp; Neutral wires around.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/melbournespaparts.com.au\/products\/hurlcon-astralpool-raypak-gas-valve-477142-477143\" style=\"color: #000000;\" title=\"Replacement for 477142\"\u003eHurlcon part number 477142 was Replaced by 477143\u003c\/a\u003e, which is now \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/hurlcon-astralpool-raypak-gas-valve?variant=10727643709497\" style=\"color: #000000;\"\u003e477143 Techrite\u003c\/a\u003e. Supersedes earlier Honeywell \u0026amp; White Rogers gas valves.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"title_desc_products_s\"\u003e\u003cstrong\u003eCurrent Valves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eON\/OFF operation\u003c\/li\u003e\n\u003cli\u003eMax Pressure: 3.5kPa\u003c\/li\u003e\n\u003cli\u003e24VAC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eReg 0.95 kPa (NG)\u003c\/li\u003e\n\u003cli\u003eT.amb -10\/80C\u003c\/li\u003e\n\u003cli\u003e1649 AGA 8054 G 1739\u003c\/li\u003e\n\u003cli\u003eCV983\u003c\/li\u003e\n\u003cli\u003eContronik CV983\u003c\/li\u003e\n\u003cli\u003eKupo CV 983\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDetails \/ Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel: CV 983\u003c\/li\u003e\n\u003cli\u003eCombination gas control include a ON-OFF switch for safety shut-off.\u003c\/li\u003e\n\u003cli\u003eSolenoid operated safety valve and burner valve by normal control for flame ignition.\u003c\/li\u003e\n\u003cli\u003eTwo automatic solenoid shut-off valves with safety valve sequencing function for direct burner ignition operation.\u003c\/li\u003e\n\u003cli\u003eMain outlet pressure adjustment\u003c\/li\u003e\n\u003cli\u003eOutlet Pressure Adjustment Range: NG 2.5\"~3.5\" W.C. \/ LPG 8\"~12\" W.C.\u003c\/li\u003e\n\u003cli\u003eMaximum Inlet Pressure: 35 mbar\u003c\/li\u003e\n\u003cli\u003eFlow Capacity (1\" W.C. Pressure Drop): NG: 150,000 BTU\/hr \/ LPG: 243,000 BTU\/hr\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -23°C~80°C\u003c\/li\u003e\n\u003cli\u003eMax Inlet pressure: 3.5 kPa\u003c\/li\u003e\n\u003cli\u003eMax Flow: 2.3 M3\/h (Air)\u003c\/li\u003e\n\u003cli\u003eRegulator Range: 0.7-0.1 kPa (NG)\u003c\/li\u003e\n\u003cli\u003e2.0-2.6kPA (Propane)\u003c\/li\u003e\n\u003cli\u003eRegulator Class: 3\u003c\/li\u003e\n\u003cli\u003eRegulator Grade: 20\u003c\/li\u003e\n\u003cli\u003eValve Class: 2\u003c\/li\u003e\n\u003cli\u003eTemperature Limitations: -10 + 80 ºC\u003c\/li\u003e\n\u003cli\u003eVoltages: 24 and 240 VAC\u003c\/li\u003e\n\u003cli\u003eMounting Limitations: Any position except coil facing down\u003c\/li\u003e\n\u003cli\u003eConnections: 15mm (1\/2\") BSP(1SO7)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Valves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eON\/OFF operation\u003c\/li\u003e\n\u003cli\u003eMax Pressure: 3.5kPa\u003c\/li\u003e\n\u003cli\u003e24VAC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eReg 0.95 kPa (NG)\u003c\/li\u003e\n\u003cli\u003eT.amb -10\/80C\u003c\/li\u003e\n\u003cli\u003e1649 AGA 8054 G 1739\u003c\/li\u003e\n\u003cli\u003eCV983 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"title_desc_products_s\"\u003e\u003cstrong\u003eOlder Valves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eON\/OFF operation\u003c\/li\u003e\n\u003cli\u003eElectronic control\u003c\/li\u003e\n\u003cli\u003eRedundant valve\u003c\/li\u003e\n\u003cli\u003eCapacities up to 140 MJ\/h\u003c\/li\u003e\n\u003cli\u003eOutlet \/ Inlet 15 or 20 mm\u003c\/li\u003e\n\u003cli\u003ePressure rating 5 kPa\u003c\/li\u003e\n\u003cli\u003eOptional slow opening\u003c\/li\u003e\n\u003cli\u003eOptional pilot tap\u003c\/li\u003e\n\u003cli\u003eOptional TRECI modulator - 0-10v DC, 0-24v DC\u003c\/li\u003e\n\u003cli\u003e36E06-30* \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eHX 120 Gas Valve, HX 70 Gas Valve\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eManufacturer Catalogues, Diagrams \u0026amp; Part Numbers\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eNeed exploded views, spare part numbers, product numbers, diagrams, or more product information? See the manufacturer catalogues:\n \u003ca href=\"https:\/\/hasp.com.au\/pages\/Astralpool_Catalogue_2026\"\u003eAstralpool Catalogue 2026\u003c\/a\u003e | \u003ca href=\"https:\/\/hasp.com.au\/pages\/Zodiac_Catalogue_2026\"\u003eZodiac Catalogue 2026\u003c\/a\u003e\n\u003c\/strong\u003e\u003c\/p\u003e\u003chr\u003e\u003ch3\u003eInteractive Parts Diagrams\u003c\/h3\u003e\u003c!-- hasp-parts-diagrams --\u003e\u003cp style=\"font-size:16px;\"\u003eFind this part on our interactive heater parts diagrams — each one opens the full exploded view and parts list:\u003c\/p\u003e\u003cul\u003e\u003cli style=\"font-size:16px;\"\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/pages\/astralpool-hurlcon-hx-120-gas-heater-spare-parts-diagram-list\" style=\"color:#009BDB;font-weight:600;\"\u003eAstralpool \/ Hurlcon HX 120 Gas Heater — Diagram \u0026amp; Parts\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Astralpool","offers":[{"title":"New Style - See notes","offer_id":44515735371965,"sku":"477143","price":741.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/astralpool-hurlcon-gas-regulator-valve-for-hx-70-120-jx-130-160-and-wx-heaters-new-style-see-notes-heater-parts-903.webp?v=1780305499","url":"https:\/\/heaterandspaparts.com.au\/en-nz\/products\/hurlcon-astralpool-raypak-gas-valve","provider":"Heater and Spa Parts","version":"1.0","type":"link"}