SALE - FREE SHIPPING.
The latest in Spa & Pool Heating, specified & distributed by the the largest spa & pool parts tributor in Australia and New Zealand. The Super Quiet Sensa Heat PI is a high-end Premium Heat Pump. Designed specifically for the Australian market, by an Australian company.
The TD Series is packed with the advanced features of the Sensaheat range with the added advantage of having a top discharge airflow, making the TD model highly versatile in confined installations.
- Top discharge airflow, air flows in from the side and discharges from the top, making the TD Series ideal for tighter installations)
- Wi-Fi as standard
- Highly efficient inverter technology
- Reverse cycle (heat and cool mode ) with auto defrost
- Easy to use digital controller
- R32 Eco-friendly refrigerant
- Titanium heat exchanger with a 25-year warranty
These heat pumps are 3-7 times more efficient than a standard heater element in a spa. On display at our showroom at 10 Industry Blvd, Carrum Downs, Vic. Shipping Australia-wide.
Pool Heater Sizing Guide Based on 10-Hour Max Run Time & Pool Cover *
Volume |
Season |
Melbourne |
Sydney |
Canberra
|
Brisbane |
Adelaide |
Perth |
Hobart |
20,000l |
Nov-Mar |
13kW |
9kW |
16kW |
9kW |
9kW |
9kW |
16kW |
|
Oct-April |
20kW |
13kW |
22kW |
9kW |
13kW |
13kW |
22kW |
|
Year-Round |
32kW |
24kW |
40kW |
20kW |
27kW |
24kW |
40kW |
|
|
|
|
|
|
|
|
|
30,000l |
Nov-Mar |
20kW |
13kW |
22kW |
9kW |
13kW |
9kW |
22kW |
|
Oct-April |
27kW |
20kW |
40kW |
13kW |
20kW |
20kW |
40kW |
|
Year-Round |
48kW |
40kW |
60kW |
27kW |
40kW |
40kW |
60kW |
|
|
|
|
|
|
|
|
|
40,000l |
Nov-Mar |
24kW |
16kW |
32kW |
9kW |
20kW |
13kW |
32kW |
|
Oct-April |
40kW |
27kW |
48kW |
20kW |
24kW |
24kW |
48kW |
|
Year-Round |
60kW |
48kW |
72kW |
40kW |
60kW |
48kW |
72kW |
|
|
|
|
|
|
|
|
|
50,000l |
Nov-Mar |
32kW |
20kW |
40kW |
9kW |
22kW |
14kW |
40kW |
|
Oct-April |
48kW |
32kW |
60kW |
22kW |
32kW |
32kW |
60kW |
|
Year-Round |
72kW |
60kW |
120kW |
48kW |
72kW |
60kW |
120kW |
|
|
|
|
|
|
|
|
|
60,000l |
Nov-Mar |
40kW |
22kW |
48kW |
13kW |
27kW |
22kW |
48kW |
|
Oct-April |
60kW |
40kW |
72kW |
27kW |
40kW |
40kW |
72kW |
|
Year-Round |
96kW |
80kW |
120kW |
60kW |
80kW |
80kW |
120kW |
|
|
|
|
|
|
|
|
|
80,000l |
Nov-Mar |
48kW |
13kW |
60kW |
18kW |
40kW |
26kW |
60kW |
|
Oct-April |
80kW |
55kW |
96kW |
40kW |
48kW |
48kW |
96kW |
|
Year-Round |
120kW |
96kW |
135kW |
80kW |
120kW |
96kW |
135kW |
|
|
|
|
|
|
|
|
|
100,000l |
Nov-Mar |
64kW |
20kW |
80kW |
18kW |
44kW |
28kW
|
80kW |
|
Oct-April |
96kW |
64kW |
120kW |
44kW |
64kW |
64kW
|
120kW |
|
Year-Round |
140kW |
120kW |
240kW |
96kW |
140kW
|
120kW
|
240kW |
Spa Heater Sizing Guide **
|
5° Per Hour (Max) |
10° Per Hour (Max) |
20° Per Hour (Max) |
1000l |
6kW |
12kW |
24kW |
1,500l |
9kW |
18kW |
36kW |
2,500l |
15kW |
29kW |
58kW |
5,000l |
29kW |
58kW |
116kW |
10,000l |
58kW |
116kW |
232kW |
* These values are calculated using the average temperature, humidity and wind speed in the location listed. The above table lists sizes for an extended season with a swimming temperature of 28 degrees Celsius.
Calculations are based on average pool dimensions for an in-ground pool using a cover with a run time of 10 hours a day with an average wind exposure and standard shading.
** Spa temperature rises are based on an insulated spa with thermal hard cover & ideal conditions. Temperature rises are a maximum theoretical temperature rise for water and based on the maximum output of a heat pump.
Where possible we recommend going at least one size above to avoid dissapointment. These tables are a guide to be used as a guide only and we take no responsiblity for innaccurate sizing, as there are too many variable to account for all scenarios.
Features & Specifications:
- Brand: Sensa-Heat
- Top Discharge Air Outlet
- Heating & Cooling
- DC Inverter Technology
- Super-Quiet
- Digital thermostat control
- Wi-Fi Control Standard
- Can directly control a pump up to 500W (2/3HP), or use the Intelli-Heat controller to control a larger pump.
- DC Brushless Fan Motor
- COP
- DC Mitsubishi Inverter
- Comes with R32 Eco-friendly gas. Can also use R410A.
- Twisted Titanium Heat Exchanger
- Aluminium alloy casing
- Automatic Defrost
- Boost Mode & Silence Mode
- Can perform with air temp of -10°C to +43°C
- Information Sheet
- User & Installation Manual
Warranty Information
- Heat Exchanger: 25 Years*
- Compress: 5 Years*
- Other Parts: 2 Years*
- On-Site Labour: 1 Year*
- * -- See T&C for full details.
Heat Pump model |
Heat Exchanger* |
Compressor* |
Parts* |
On-Site Labor* |
ES Series - Eco |
25 years |
3 years |
2 years |
1 year |
PI Series - Premium
|
25 years |
5 years |
2 years |
1 year |
TD - Top Discharge
|
25 years |
5 years |
2 years |
1 year |
13kW Heater - HPTD13 ( Amps Needed)
- Heating Capacity: 13.5kW
- COP: 15-6.9 / Average: 11.5
- Cooling Capacity: 6.0kW
- Operating Temperature: -10-43°
- Max Current: 12A
- 220-240V 1-Phase
- 50mm Water Connection
- Dimensions: 780mm x 820mm x 690mm
- Weight: 67kW
16kW Heater - HPTD16 ( Amps Needed)
- Heating Capacity: 16.5kW
- COP: 15.2-7.2 / Average: 11.6
- Cooling Capacity: 7.3
- Operating Temperature: -10-43°
- Max Current: 13.5A
- 220-240V 1-Phase
- 50mm Water Connection
- Dimensions: 780mm x 820mm x 690mm
- Weight: 70kg
21kW Heater - HPTD21 ( Amps Needed)
- Heating Capacity: 21kW
- COP: 15.9-7.0 / Average: 11.8
- Cooling Capacity: 9.0
- Operating Temperature: -10-43°
- Max Current: 17A
- 220-240V 1-Phase
- 50mm Water Connection
- Dimensions: 780mm x 820mm x 690mm
- Weight: 77kg
26kW Heater - HPTD26 ( Amps Needed)
- Heating Capacity: 26kW
- COP: 15.0-6.9 / Average: 11.5
- Cooling Capacity: 11.2
- Operating Temperature: -10-43°
- Max Current: 20A
- 220-240V 1-Phase
- 50mm Water Connection
- Dimensions: 780mm x 820mm x 756mm
- Weight: 88kg