{"product_id":"impeller-viron-xt-p520","title":"Astralpool Impeller Viron XT P520 40060Z","description":"\u003c!-- HASP-FLP-1.0 | SKU 40060Z | rule VIR-2.0 | canary: five-vane-echo --\u003e\n\u003ch3\u003eAstralpool Impeller Viron XT P520 40060Z\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine Astralpool impeller, part number \u003cstrong\u003e40060Z\u003c\/strong\u003e, for the \u003cstrong\u003eViron XT P520\u003c\/strong\u003e variable speed pool pump. The same part number covers every generation of the XT P520 from the original release through to the current P520 C XT. It is visibly larger than the P320 impeller and the two are not interchangeable. It is also \u003cem\u003enot\u003c\/em\u003e the impeller for the Viron eVo range.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe Viron XT Impeller Rule (rev. VIR-2.0)\u003c\/h3\u003e\n\u003cp\u003eAlmost every wrong impeller sent for these pumps comes from ordering by the number on the pump rather than the letters after it, or from assuming a P320 and P520 share parts. They do not. Work through these four steps in order and finish on a measurement:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead the full model line on the pump badge, not just the number.\u003c\/strong\u003e You are looking for the letters immediately after the number: \u003cem\u003eXT\u003c\/em\u003e, \u003cem\u003eeVo\u003c\/em\u003e, or \u003cem\u003eC XT\u003c\/em\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf the badge says eVo, stop here.\u003c\/strong\u003e The eVo range uses the older CX \/ P280 \/ FX family impeller and this part will not fit it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf the badge says XT or C XT, continue — the year does not matter.\u003c\/strong\u003e Isolate power, open the wet end, remove the impeller retaining bolt and withdraw the impeller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure the outside diameter across the widest point and the vane width at the outer edge.\u003c\/strong\u003e If it measures approximately \u003cstrong\u003e133mm across and 8.8mm at the vane\u003c\/strong\u003e, you have the smaller \u003cstrong\u003eP320\u003c\/strong\u003e impeller and you need \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/astralpool-p320-xt-impeller\"\u003e40060X\u003c\/a\u003e instead. The P520 impeller is noticeably larger than that.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eWorked Example\u003c\/h3\u003e\n\u003cp\u003eA Viron XT P520 running a 96,000 litre pool with an in-floor cleaning system had been losing pressure at the floor heads for two seasons, and the previous service had already replaced the mechanical seal without improvement. On strip-down the impeller was found to be a P320 unit — fitted years earlier by someone who had ordered by the badge number alone. The pump had been running at roughly two-thirds of its intended flow ever since, and the controller had thrown intermittent over-current faults. Fitting the correct 40060Z restored full head at the floor heads on medium speed.\u003c\/p\u003e\n\n\u003ch3\u003eWhich Impeller Do I Need?\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIf your pump badge reads\u003c\/th\u003e\n\u003cth\u003eAnd the old impeller measures\u003c\/th\u003e\n\u003cth\u003eYou need\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eViron XT P520, XT Series 2 P520, P520 C XT\u003c\/td\u003e\n\u003ctd\u003enoticeably larger than 133mm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40060Z — this product\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViron XT P320, XT Series 2 P320, P320 C XT\u003c\/td\u003e\n\u003ctd\u003eapprox. 133mm dia, 8.8mm vane\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/astralpool-p320-xt-impeller\"\u003eImpeller Viron XT P320 — 40060X\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViron eVo, CX320, P280, FX290\u003c\/td\u003e\n\u003ctd\u003edifferent hub and vane profile\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/hurlcon-astralpool-bx-tx-impellers\"\u003eHurlcon \/ Astralpool BX \/ TX impeller range\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eEvery Model and Generation This Impeller Fits\u003c\/h3\u003e\n\u003cp\u003eAstralpool revised the Viron XT several times without ever changing the P520 impeller part number. If your pump is badged XT, the 40060Z is correct regardless of its age or which of the revisions below it belongs to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P520 XT\u003c\/strong\u003e — original XT release, including all early-production units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P520 XT, pre-July 2018 wet end\u003c\/strong\u003e — wet end 40097, seal plate 40098, mechanical seal 75508. Impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P520 XT, July 2018 onwards wet end\u003c\/strong\u003e — revised wet end 40031 and seal plate 40030, mechanical seal 75509. Impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT Series 2 \/ XT MkII P520\u003c\/strong\u003e — revised controller and housing. Impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT P520C (Nov 2020 – June 2021)\u003c\/strong\u003e — impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT P520C (July 2021 onwards)\u003c\/strong\u003e — impeller unchanged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P520 C XT\u003c\/strong\u003e — the current model, which supersedes the earlier P520 XT variants. Impeller unchanged.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn short: the wet end, seal plate and mechanical seal were all revised over the life of the XT P520, but the impeller has stayed 40060Z throughout. If you are ordering other parts at the same time, those \u003cem\u003eare\u003c\/em\u003e era-dependent and you will need to identify your pump's build date.\u003c\/p\u003e\n\n\u003ch3\u003eWhat This Impeller Does Not Fit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron XT P320 and P320 C XT\u003c\/strong\u003e — smaller hydraulic package, smaller impeller. Fitting a P520 impeller to a P320 overloads the motor and is a listed cause of the HI A over-current fault. Use \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/astralpool-p320-xt-impeller\"\u003e40060X\u003c\/a\u003e instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron eVo range\u003c\/strong\u003e — a different pump generation with a different wet end, sharing its impeller with the CX320 \/ P280 \/ FX290 family. Start with the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/hurlcon-astralpool-bx-tx-impellers\"\u003eHurlcon \/ Astralpool impeller range\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P520 (original, pre-eVo)\u003c\/strong\u003e — carries its own separate parts breakdown and a different impeller. \u003ca href=\"mailto:info@hasp.com.au\"\u003eSend us a photo of your pump badge\u003c\/a\u003e and we will identify it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eViron P600 and CTX series\u003c\/strong\u003e — different wet end and different part number entirely. \u003ca href=\"mailto:info@hasp.com.au\"\u003eContact us\u003c\/a\u003e with your model details.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHurlcon BX, TX, E-series and older CTX pumps\u003c\/strong\u003e — pre-Viron wet ends. See the \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/hurlcon-astralpool-bx-tx-impellers\"\u003eBX \/ TX impeller range\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHost Pump Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eViron P520 XT motor output: 1.5 kW, 240V 50Hz, 6.0 amp, maximum 2820 rpm\u003c\/li\u003e\n\u003cli\u003eFlow rates: 520 lpm high (2850 rpm), 426 lpm medium (2000 rpm), 200 lpm low (1125 rpm)\u003c\/li\u003e\n\u003cli\u003eFor comparison, the P320 XT is 0.75 kW \/ 4.1 amp and 320 lpm on high — which is why the impellers differ\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFitting Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRetained by impeller retaining bolt \u003cstrong\u003e78187\u003c\/strong\u003e with o-ring \u003cstrong\u003e78711\u003c\/strong\u003e — inspect both on removal and replace if the o-ring is flattened or the bolt is corroded\u003c\/li\u003e\n\u003cli\u003eMatching mechanical seal: 75509 on current and post-2018 pumps, 75508 on the earliest XT builds\u003c\/li\u003e\n\u003cli\u003eMatching diffuser: \u003cstrong\u003e40071B\u003c\/strong\u003e (XT P520). The XT P320 takes 40071A — do not mix them\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSymptoms of a Failed or Worn Impeller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotor runs at normal speed and normal noise, but flow and filter pressure are both down\u003c\/li\u003e\n\u003cli\u003eIn-floor cleaning heads or spa jets no longer reaching pressure at the speed they used to\u003c\/li\u003e\n\u003cli\u003ePump takes far longer to prime, or will not hold prime, with no air leak found on the suction side\u003c\/li\u003e\n\u003cli\u003eGrinding, rattling or a rhythmic knock from the wet end\u003c\/li\u003e\n\u003cli\u003ePump humming but not turning — debris jammed in the impeller is a listed cause in the Astralpool troubleshooting guide, often after the hair and lint basket has split and allowed debris through\u003c\/li\u003e\n\u003cli\u003eController showing the \u003cstrong\u003eHI A\u003c\/strong\u003e over-current fault — Astralpool lists \"wrong impeller fitted\" as one of the causes\u003c\/li\u003e\n\u003cli\u003eVisible debris packed into the vane passages, or vane tips worn back and rounded\u003c\/li\u003e\n\u003cli\u003eCracked or spun hub after the pump has run dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cp\u003eReplace the impeller when the vanes are worn, chipped or cracked, when the hub has spun, or when the pump has run dry and the plastic has distorted. Blocked vanes can often be cleared rather than replaced — check that first. Because the mechanical seal is disturbed whenever the impeller comes off, we recommend fitting a new \u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/3-4-mechanical-seal\"\u003emechanical seal\u003c\/a\u003e at the same time rather than reusing a seal whose faces have been separated.\u003c\/p\u003e\n\n\u003ch3\u003ePart Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40060Z\u003c\/strong\u003e — Astralpool impeller, Viron XT P520, all generations (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40060X\u003c\/strong\u003e — Astralpool impeller, Viron XT P320 (\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/astralpool-p320-xt-impeller\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78187\u003c\/strong\u003e — impeller retaining bolt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78711\u003c\/strong\u003e — impeller retaining bolt o-ring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e75509\u003c\/strong\u003e — mechanical seal, current \/ post-2018 pumps (\u003ca href=\"https:\/\/heaterandspaparts.com.au\/products\/3-4-mechanical-seal\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e75508\u003c\/strong\u003e — mechanical seal, earliest XT builds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40071B\u003c\/strong\u003e — diffuser, XT P520 (40071A for XT P320)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78104\u003c\/strong\u003e — diffuser o-ring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40065\u003c\/strong\u003e — pump basket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40089\u003c\/strong\u003e — lid complete with o-ring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21489\u003c\/strong\u003e — controller, P520\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e71462\u003c\/strong\u003e — motor, P520\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40097 \/ 40031\u003c\/strong\u003e — pump wet end, pre- and post-July 2018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40098 \/ 40030\u003c\/strong\u003e — seal plate, pre- and post-July 2018\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 40060Z and 40060X?\u003c\/strong\u003e\u003cbr\u003e40060Z is the P520 impeller and 40060X is the P320 impeller. The P520 impeller is physically larger because the P520 is a higher flow pump, running a 1.5 kW motor against the P320's 0.75 kW. They are not interchangeable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this fit older Viron XT P520 pumps?\u003c\/strong\u003e\u003cbr\u003eYes. The impeller part number has never changed across the life of the XT P520. It covers the original XT, the pre-2018 and post-2018 wet end revisions, the XT Series 2, the P520C and the current P520 C XT.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit a P520 impeller to a P320 to get more flow?\u003c\/strong\u003e\u003cbr\u003eNo. The P320 motor is half the output of the P520 and will draw excessive current trying to turn the larger impeller. Astralpool lists a wrong impeller being fitted as a cause of the HI A over-current fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 40060Z fit a Viron eVo?\u003c\/strong\u003e\u003cbr\u003eNo. The eVo is a different pump generation and uses the impeller shared with the CX320, P280 and FX290 pumps. Only the XT and C XT versions of the P520 take the 40060Z.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the impeller held on?\u003c\/strong\u003e\u003cbr\u003eThe Viron XT impeller is secured by a retaining bolt, part 78187, with an o-ring, part 78711. Remove the bolt before attempting to withdraw the impeller, and inspect the o-ring while it is apart.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a new mechanical seal when I replace the impeller?\u003c\/strong\u003e\u003cbr\u003eWe recommend it. The mechanical seal is split apart as soon as the impeller comes off, and reused seal faces are the most common cause of a leak after an impeller change.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy pump runs but flow has dropped — is the impeller the cause?\u003c\/strong\u003e\u003cbr\u003ePossibly, but check the easy items first: skimmer and pump baskets, lid o-ring, suction blockages and a dirty filter. If those are clear and the motor is running at full speed, a worn or blocked impeller is the next thing to inspect.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Astralpool part?\u003c\/strong\u003e\u003cbr\u003eYes. We are an authorised Astralpool and Fluidra dealer and warranty agent, and this is the genuine 40060Z impeller.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer Catalogues, Diagrams \u0026amp; Part Numbers\u003c\/h3\u003e\n\u003cp\u003eNeed exploded views, spare part numbers, product numbers or diagrams? See the manufacturer catalogue: \u003ca href=\"https:\/\/hasp.com.au\/pages\/Astralpool_Catalogue_2026\"\u003eAstralpool Catalogue 2026\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e confirm this part is correct for your pump. Use the catalogue above, seek professional assistance, or \u003ca href=\"mailto:info@hasp.com.au\"\u003econtact us\u003c\/a\u003e with photos of your existing part, model details, serial numbers and any labels. As with all products, this must be diagnosed and fitted by a qualified and experienced person. This is a \u003ca href=\"https:\/\/heaterandspaparts.com.au\/policies\/refund-policy\" rel=\"noopener\" target=\"_blank\"\u003especial-order\u003c\/a\u003e item.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eCommon search terms: Astralpool 40060Z, Viron XT P520 impeller, Astral P520XT impeller, Viron P520C impeller, Hurlcon Viron P520 impeller, Viron XT Series 2 impeller, Viron variable speed pump impeller replacement.\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- HASP-FLP-1.0 end | canary: five-vane-echo --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between 40060Z and 40060X?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"40060Z is the P520 impeller and 40060X is the P320 impeller. The P520 impeller is physically larger because the P520 is a higher flow pump, running a 1.5 kW motor against the P320's 0.75 kW. They are not interchangeable.\"}},{\"@type\":\"Question\",\"name\":\"Does this fit older Viron XT P520 pumps?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The impeller part number has never changed across the life of the XT P520. It covers the original XT, the pre-2018 and post-2018 wet end revisions, the XT Series 2, the P520C and the current P520 C XT.\"}},{\"@type\":\"Question\",\"name\":\"Can I fit a P520 impeller to a P320 to get more flow?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The P320 motor is half the output of the P520 and will draw excessive current trying to turn the larger impeller. Astralpool lists a wrong impeller being fitted as a cause of the HI A over-current fault.\"}},{\"@type\":\"Question\",\"name\":\"Does the 40060Z fit a Viron eVo?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The eVo is a different pump generation and uses the impeller shared with the CX320, P280 and FX290 pumps. Only the XT and C XT versions of the P520 take the 40060Z.\"}},{\"@type\":\"Question\",\"name\":\"How is the impeller held on?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The Viron XT impeller is secured by a retaining bolt, part 78187, with an o-ring, part 78711. Remove the bolt before attempting to withdraw the impeller, and inspect the o-ring while it is apart.\"}},{\"@type\":\"Question\",\"name\":\"Do I need a new mechanical seal when I replace the impeller?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"We recommend it. The mechanical seal is split apart as soon as the impeller comes off, and reused seal faces are the most common cause of a leak after an impeller change.\"}},{\"@type\":\"Question\",\"name\":\"My pump runs but flow has dropped - is the impeller the cause?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Possibly, but check the easy items first: skimmer and pump baskets, lid o-ring, suction blockages and a dirty filter. If those are clear and the motor is running at full speed, a worn or blocked impeller is the next thing to inspect.\"}},{\"@type\":\"Question\",\"name\":\"Is this a genuine Astralpool part?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. We are an authorised Astralpool and Fluidra dealer and warranty agent, and this is the genuine 40060Z impeller.\"}}]},{\"@type\":\"HowTo\",\"name\":\"The Viron XT Impeller Rule (rev. VIR-2.0)\",\"description\":\"How to confirm whether your Astralpool Viron pump takes the 40060Z P520 impeller.\",\"step\":[{\"@type\":\"HowToStep\",\"name\":\"Read the full model line\",\"text\":\"Read the full model line on the pump badge, not just the number. Look for the letters immediately after the number: XT, eVo, or C XT.\"},{\"@type\":\"HowToStep\",\"name\":\"Rule out the eVo\",\"text\":\"If the badge says eVo, stop. The eVo range uses the older CX, P280 and FX family impeller and the 40060Z will not fit it.\"},{\"@type\":\"HowToStep\",\"name\":\"Remove the impeller\",\"text\":\"If the badge says XT or C XT the year does not matter. Isolate power, open the wet end, remove the impeller retaining bolt and withdraw the impeller.\"},{\"@type\":\"HowToStep\",\"name\":\"Measure\",\"text\":\"Measure the outside diameter across the widest point and the vane width at the outer edge. If it measures approximately 133mm across and 8.8mm at the vane you have the smaller P320 impeller, part 40060X. The P520 impeller is noticeably larger.\"}]}]}\n\u003c\/script\u003e","brand":"FLUIDRA","offers":[{"title":"Default Title","offer_id":46836086112445,"sku":"40060Z","price":78.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/astralpool-impeller-viron-xt-p520-40060z-pool-pump-parts-856.webp?v=1784679737","url":"https:\/\/heaterandspaparts.com.au\/zh-hans\/products\/impeller-viron-xt-p520","provider":"Heater and Spa Parts","version":"1.0","type":"link"}