Hayward Gas Heater Parts List - H150FD, H250FD, H400FD
Hayward Gas Heater Parts List - H150FD, H250FD, H400FD - is temporarily out of stock and will ship as soon as it's available.
Don't Guess - Ask Us!
Don't Guess - Ask Us!
Not sure if it’s the right part? Send us a message and a photo of what you’re replacing, or what you need, and we’ll help make sure you get the right part the first time.
Delivery and Shipping Info*
Delivery and Shipping Info*
Free Shipping over $99 for most products. Choose Express Post for fastest shipping!
Hayward Gas Heater Parts List - H150FD, H250FD, H400FD - is temporarily out of stock and will ship as soon as it's available.
Genuine Hayward spare parts for H150FD, H250FD and H400FD gas pool and spa heaters (Australian 50 Hz models). Choose the part you need from the drop-down. The numbers match the item numbers on the exploded parts diagram shown in the product images. Parts listed as NS have no item number on the diagram.
Availability and lead times
These are special-order parts. They are not stocked in our warehouses and are brought in from the manufacturer as required.
Lead times on Hayward spare parts are set by the supplier and are outside our control. We cannot guarantee a delivery date at the time you order, and any timeframe we quote is an estimate only and may change. We will confirm the best ETA we have once your order is placed, and keep you updated as it progresses.
Check before you order
Match the part number against your heater's data plate and the parts diagram before ordering. These parts are brought in specifically for your order, so they cannot be returned or exchanged for change of mind or for an incorrect selection. This does not limit your rights under the Australian Consumer Law.
Not sure which part you need?
Send us your heater model and serial number and we will confirm the correct part number before you order. Note, we cannot diagnose remotely.
To the layperson, plumbing sizes and their names can be confusing due to the nominal sizes and naming conventions used.
This is not something we made up. Plumbers and manufacturers have used nominal (meaning ‘by name only’) sizing for decades.
Simply put, in plumbing, named sizes are often not the actual measurements of the pipe, fitting, or part. A PVC pipe called “50mm” or “2"” does not measure 50 mm anywhere. Instead, it follows nominal sizing, an internationally-standardised naming system.
Almost all fittings we use in the pool & spa industry use “pressure PVC” pipe & fittings. Do not confuse with “DWV” or other pipe & fittings and their names and sizes.
Use the Outside Diameter (OD) to check your pipe against fittings. Below is a quick reference for common spa & pool pipe sizes:
| Imperial Name | Metric Name | Pipe Diameter (OD) |
|---|---|---|
| 1/2" | 15mm | ~21.2–21.5 mm |
| 3/4" | 20mm | ~26.6–26.9 mm |
| 1" | 25 mm | ~33.4–33.7 mm |
| 1.5" | 40 mm | ~48.1–48.4 mm |
| 2" | 50 mm | ~60.2–60.8 mm |
| 2.5" | 65 mm | ~75.2–75.5 mm |
To reiterate, these are nominal sizes and are designed to fit matching fittings — not to measure what their name suggests. These are based on PVC Pressure Pipe AS/NZ 1477 Dimensions1.
- º Internal diameters vary slightly by manufacturer and class.
- 1 Not all pool/spa fittings match these dimensions exactly. Some do not follow Australian or international standards. Chinese spas may use proprietary fittings.
Understanding Plumbing Sizes & Nominal Measurements
Plumbing sizes can be confusing. PVC and many other pipe systems use nominal sizes—the size is a name, not the exact measured dimension. This convention is used across most pool and spa systems and other plumbing areas so that pipes and fittings remain compatible.
Why pipe sizes don’t match the measurements
The Nominal Pipe Size (NPS) system standardises pipe dimensions so that pipes, fittings, valves, and accessories interoperate.
Plumbers work with these nominal names every day, but DIYers can be tripped up if they try to match by a tape-measure alone.
How to Measure Pipe Correctly
-
Pipe size is identified by:
- The pipe’s Outside Diameter (OD).
- The fitting’s Inside Diameter (ID) (socket opening).
- Pipe Class / Schedule (e.g., Class 9, 12, 18 or Sch 40) relates to wall thickness and therefore the Internal Diameter (ID) and pressure rating.
- The outside diameter of a fitting is not useful (wall thickness varies by manufacturer).
Hose & Tube Dimensions
Common flexible hose sizes used in pool/spa systems (approximate IDs).
| Imperial Name | Metric Name | Inside Diameter (ID) |
|---|---|---|
| 3/8" | 9–10 mm | ~9 mm |
| 3/4" | 19 mm | ~19 mm |
BSP – British Standard Pipe Thread Sizes
BSP thread names are also nominal. The thread OD will not equal the nominal name.
| BSP Thread Size Naming | Outside Diameter (mm / inch) | TPI |
|---|---|---|
| 1/16" BSP | 7.7 mm / 0.304" | 28 |
| 1/8" BSP | 9.7 mm / 0.383" | 28 |
| 1/4" BSP | 13.16 mm / 0.518" | 19 |
| 3/8" BSP | 16.66 mm / 0.656" | 19 |
| 1/2" BSP / 15 mm | 20.99 mm / 0.825" | 14 |
| 5/8" BSP | 22.99 mm / 0.902" | 14 |
| 3/4" BSP / 20 mm | 26.44 mm / 1.041" | 14 |
| 7/8" BSP | 30.20 mm / 1.189" | 14 |
| 1" BSP / 25 mm | 33.25 mm / 1.309" | 11 |
| 1-1/4" BSP | 41.91 mm / 1.650" | 11 |
| 1-1/2" BSP / 40 mm | 47.80 mm / 1.882" | 11 |
| 2" BSP / 50 mm | 59.61 mm / 2.347" | 11 |
| 2-1/4" BSP | 65.71 mm / 2.587" | 11 |
| 2-1/2" BSP | 75.18 mm / 2.960" | 11 |
| 3" BSP | 87.88 mm / 3.460" | 11 |
| 4" BSP | 113.03 mm / 4.450" | 11 |
| 5" BSP | 138.43 mm / 5.450" | 11 |
| 6" BSP | 163.83 mm / 6.450" | 11 |
Payment & Security